Functional description – Rainbow Electronics ADC08138 User Manual

Page 13

Advertising
background image

Functional Description

(Continued)

TABLE II MUX Addressing ADC08138

(Continued)

Differential MUX Mode

MUX Address

Analog Differential Channel-Pair

START

SGL

ODD

SELECT

0

1

2

3

DIF

SIGN

1

0

0

1

2

3

4

5

6

7

1

0

0

0

0

a

b

1

0

0

0

1

a

b

1

0

0

1

0

a

b

1

0

0

1

1

a

b

1

0

1

0

0

b

a

1

0

1

0

1

b

a

1

0

1

1

0

b

a

1

0

1

1

1

b

a

TABLE III MUX Addressing ADC08134

Single-Ended MUX Mode

MUX Address

Channel

START

SGL

ODD

SELECT

0

1

2

3

DIF

SIGN

1

1

1

0

0

a

1

1

0

1

a

1

1

1

0

a

1

1

1

1

a

COM is internally tied to AGND

Differential MUX Mode

MUX Address

Channel

START

SGL

ODD

SELECT

0

1

2

3

DIF

SIGN

1

1

0

0

0

a

b

1

0

0

1

a

b

1

0

1

0

b

a

1

0

1

1

b

a

13