Max8620y – Rainbow Electronics MAX8620 User Manual

Page 10

Advertising
background image

MAX8620Y

LDO Output-Voltage

Selection (SEL1, SEL2)

As shown in

Table 1, the LDO output voltages, OUT1

and OUT2, are set according to the logic states of
SEL1 and SEL2. SEL1 and SEL2 are trilevel inputs: IN1,
open, and GND. The input voltage, V

IN1

, must be a

dropout voltage (V

DO

) greater than the selected OUT1

and OUT2 voltages.

Power-Enable Input (PWR_ON)

Drive PWR_ON low to place the MAX8620Y in power-
down mode and reduce supply current to 5.5µA (typ).
Connect PWR_ON to IN1 = IN2 or logic-high to enable
the MAX8620Y. EN2 enables and disables OUT2 when

PWR_ON is high (Table 2). OUT1, OUT2, and OUT3 are
all disabled when PWR_ON is low. HF_PWR can tem-
porarily bring the MAX8620 out of power-down mode
when PWR_ON is low (see the HF_PWR section). In
power-down, the control circuitry, internal-switching p-
channel MOSFET, and the internal synchronous rectifier
(n-channel MOSFET) turn off, and LX becomes high
impedance. In addition, both LDOs are disabled.

OUT2 Enable (

EN2

)

Drive EN2 low to enable OUT2. Drive EN2 high to dis-
able OUT2. If the MAX8620Y is placed into power-
down using PWR_ON (PWR_ON = low), OUT2 does not
power regardless of the status of EN2 (Table 2).

µPMIC for Microprocessors or DSPs
in Portable Equipment

10

______________________________________________________________________________________

ON/OFF

LOGIC

1.25V

REF

87%

REGULATION

P

OUT1

RESET

GND

IN1

LDO THERMAL

SENSOR

MOS DRIVER

WITH I

LIMIT

MOS DRIVER

WITH I

LIMIT

POK

EN2

ERROR-

AMP 2

ERROR-

AMP 1

P

OUT2

PWR_ON

HF_PWR

BP

TIMER

MAX8620Y

Figure 3. Linear-Regulator Functional Diagram

Advertising