Data/DCLK Timing (03h)

BIT 7

BIT 6

BIT 5

BIT 4

BIT 3

BIT 2

BIT 1

BIT 0

DA_BYPASS

DLY_HALF_T

DCLKTIME_2

DCLKTIME_1

DCLKTIME_0

DTIME_2

DTIME_1

DTIME_0

Bit 7

DA_BYPASS: Data aligner bypass

0 = Nominal

1 = Bypasses data aligner delay line to minimize output data latency with respect to the input clock.

Rising clock to data transition is approximately 6ns with DTIME = 000b settings (default)

Bit 6

DLY_HALF_T: Data and DCLK delayed by T/2

0 = Normal, no delay (default)

1 = Delays data and DCLK outputs by T/2

Disabled in MUX data bus mode

Bit 5, 4, 3

DCLKTIME_2, DCLKTIME_1, DCLKTIME_0: DCLK timing adjust (controls both channels)

000 = Nominal (default)

001 = +T/16

010 = +2T/16

011 = +3T/16

100 = Reserved, do not use

101 = -1T/16

110 = -2T/16

111 = -3T/16

Bit 2, 1, 0

DTIME_2, DTIME_1, DTIME_0: Data timing adjust (controls both channels)

000 = Nominal (default)

001 = +T/16

010 = +2T/16

011 = +3T/16

100 = Reserved, do not use

101 = -1T/16

110 = -2T/16

111 = -3T/16