Pin description – Rainbow Electronics MAX6508 User Manual

Page 4

Advertising
background image

MAX6505–MAX6508

Dual Trip SOT Temperature Switches

4

_______________________________________________________________________________________

Pin Description

PIN

MAX6505

MAX6506

MAX6507

MAX6508

NAME

FUNCTION

1

-—

-—

WARN

Open-Drain Active-Low Warning Output. WARN goes low
when the die temperature exceeds T

WARN

= T

ALARM

-

∆T

AW.

-—

1

-—

-—

WARN

Push-Pull Active-High Warning Output. WARN goes high
when the die temperature exceeds T

WARN

= T

ALARM

-

∆T

AW.

2

2

2

2

GND

Ground

3, 5

3, 5

-—

-—

S1, S0

Delta Temperature Select Input. Connect to V

CC

or GND to

select the difference between T

ALARM

and T

WARN

(Table

1 or see Electrical Characteristics).

-—

-—

3

3

S0

Hysteresis Select Input. Connect to V

CC

for 10

°C

hysteresis. Connect to GND for 2

°C hysteresis.

4

4

4

4

V

CC

Supply Voltage Input. Bypass V

CC

to GND with a 0.1

µF

ceramic capacitor.

-—

-—

5

5

N.C.

No Connection. Not internally connected.

-—

-—

6

-—

OVER

Open-Drain Active-Low Overtemperature Output.

OVER

goes low when the die temperature exceeds the factory-
set value of T

OVER

.

-—

-—

_

6

OVER

Push-Pull Active-High Overtemperature Output. OVER
goes high when the die temperature exceeds the factory-
set value of T

OVER.

-—

-—

1

-—

OK

Open-Drain Active-High Temperature Sensor Output. OK
goes high impedance when the die temperature is
between the factory-set values of T

OVER

and T

UNDER

.

When the die temperature is above T

OVER

or below

T

UNDER

, OK goes low.

-—

-—

-—

1

OK

Push-Pull Active-Low Temperature Sensor Output. OK
goes low when the die temperature is between the factory-
set values of T

OVER

and T

UNDER

. When the die temp-

erature is above T

OVER

or below T

UNDER

, OK goes high.

6

-—

-—

-—

ALARM

Open-Drain Active-Low Alarm Output. ALARM goes low
when the die temperature exceeds the factory-set value of
T

ALARM

.

-—

6

-—

-—

ALARM

Push-Pull Active-High Alarm Output. ALARM goes high
when the die temperature exceeds the factory-set value of
T

ALARM

.

Advertising