Full wireless M-Bus application (optional custom specific version)

As an option, a full wireless M-Bus application layer can be integrated in the module

based on

customer specification

. In this case all the application layer protocol and timing will be

handled internally by the module. An S0 (1-pin) pulse interface and/or a serial interface can

be used to read out values from any meter. Since the protocol for reading out meter

information may differ from meter to meter, the embedded firmware is customized for each

different meter and application.

These are some of the features that can be used in a customized application:

4 kB EEPROM for storing meter data

32 kHz oscillator for real time clock time stamps

AES-128 encryption

Sleep timers

Message acknowledgement and re-transmissions

Digital I/O pins for tamper detection, alarms and installation

A/D converter for analogue sensors

One-Button Installation (optional custom specific version)

Due to the two-way transceiver capability of the RC1180-MBUS module, a simple and robust

installation procedure can be used even for S1 and T1 (one-way) operation modes.

In a full M-Bus application, the Radiocrafts unique “one-button” installation feature simplifies

the installation and reduces installation time substantially. Using an external push-button and

a LED connected to dedicated pins on the module, the installation procedure is very simple:

Press the install button on concentrator

Press the install button on meter

Wait 5 seconds for two way communication between meter and concentrator

See installation LED go on for OK installation (Blinking for error during installation)