Human Body Model

The MAX4951 is characterized for ±5.5kV ESD protec-
tion using the Human Body Model (MIL-STD-883,
Method 3015). Figure 1 shows the Human Body Model
and Figure 2 shows the current waveform it generates
when discharged into a low impedance. This model
consists of a 100pF capacitor charged to the ESD volt-
age of interest that is then discharged into the device
through a 1.5k

Ω resistor.

Power-Supply Sequencing

Caution: Do not exceed the absolute maximum rat-
ings because stresses beyond the listed ratings
may cause permanent damage to the device.

Proper power-supply sequencing is recommended for
all devices. Always apply V

CC

before applying signals,

especially if the signal is not current limited.

SATA I/SATA II Bidirectional Re-Driver

8

_______________________________________________________________________________________

Figure 2. Human Body Current Waveform

I

P

100%

90%

36.8%

t

RL

TIME

t

DL

CURRENT WAVEFORM

PEAK-TO-PEAK RINGING
(NOT DRAWN TO SCALE)

Ir

10%

0

0

AMPS

CHARGE-CURRENT

LIMIT RESISTOR

DISCHARGE

RESISTANCE

STORAGE
CAPACITOR

Cs

100pF

R

C

1M

R

D

1500

HIGH-

VOLTAGE

DC

SOURCE

DEVICE

UNDER

TEST