Pin description – Rainbow Electronics MAX6696 User Manual

Page 5

Advertising
background image

MAX6695/MAX6696

Dual Remote/Local Temperature Sensors with

SMBus Serial Interface

_______________________________________________________________________________________

5

Pin Description

PIN

MAX6695

MAX6696

NAME

FUNCTION

1

2

V

CC

Supply Voltage Input, +3V to +3.6V. Bypass to GND with a 0.1µF capacitor. A
47

Ω series resistor is recommended but not required for additional noise

filtering. See Typical Operating Circuit.

2

3

DXP1

Combined Remote-Diode Current Source and A/D Positive Input for Remote-
Diode Channel 1. DO NOT LEAVE DXP1 FLOATING; connect DXP1 to DXN if no
remote diode is used. Place a 2200pF capacitor between DXP1 and DXN for
noise filtering.

3

4

DXN

Combined Remote-Diode Current Sink and A/D Negative Input. DXN is internally
biased to one diode drop above ground.

4

5

DXP2

Combined Remote-Diode Current Source and A/D Positive Input for Remote-
Diode Channel 2. DO NOT LEAVE DXP2 FLOATING; connect DXP2 to DXN if no
remote diode is used. Place a 2200pF capacitor between DXP2 and DXN for
noise filtering.

5

10

OT1

Overtemperature Active-Low Output, Open Drain. OT1 is asserted low only when
the temperature is above the programmed OT1 threshold.

6

8

GND

Ground

7

9

SMBCLK

SMBus Serial-Clock Input

8

11

ALERT

SMBus Alert (Interrupt) Active-Low Output, Open-Drain. Asserts when
temperature exceeds user-set limits (high or low temperature) or when a remote
sensor opens. Stays asserted until acknowledged by either reading the status
register or by successfully responding to an alert response address. See the
ALERT Interrupts section.

9

12

SMBDATA

SMBus Serial-Data Input/Output, Open Drain

10

13

OT2

Overtemperature Active-Low Output, Open Drain. OT2 is asserted low only when
temperature is above the programmed OT2 threshold.

1, 16

N.C.

No Connect

6

ADD1

SMBus Slave Address Select Input (Table 10). ADD0 and ADD1 are sampled
upon power-up.

7

RESET

Reset Input. Drive RESET high to set all registers to their default values (POR
state). Pull RESET low for normal operation.

14

ADD0

SMBus Slave Address Select Input (Table 10). ADD0 and ADD1 are sampled
upon power-up.

15

STBY

Hardware Standby Input. Pull STBY low to put the device into standby mode.
All registers’ data are maintained.

Advertising