MAX15020

2A, 40V Step-Down DC-DC Converter with

Dynamic Output-Voltage Programming

_______________________________________________________________________________________

5

TURN-ON/TURN-OFF WAVEFORM

MAX15020 toc10

10ms/div

5V/div

0V

1V/div

0V

V

OUT

V

ON/OFF

V

IN

= 40V, R

LOAD

= 27

REFOUT VOLTAGE vs. TEMPERATURE

MAX15020 toc11

TEMPERATURE (

°C)

REFOUT VOLTAGE (V)

110

85

60

35

10

-15

0.97

0.99

1.01

1.03

1.05

0.95

-40

135

EFFICIENCY vs. LOAD CURRENT

MAX15020 toc12

OUTPUT CURRENT (A)

EFFICIENCY (%)

1

0.1

10

20

30

40

50

60

70

80

90

100

0

0.01

10

V

IN

= 40V

V

IN

= 24V

f

S

= 500kHz

V

OUT

= 3.3V

V

IN

= 12V

V

IN

= 7.5V

EFFICIENCY vs. LOAD CURRENT

MAX15020 toc13

OUTPUT CURRENT (A)

EFFICIENCY (%)

1

0.1

10

20

30

40

50

60

70

80

90

100

0

0.01

10

f

S

= 500kHz

V

IN

= 40V

V

OUT

= 30V

TURN-ON/TURN-OFF WAVEFORM

MAX15020 toc09

10ms/div

5V/div

0V

1V/div

0V

V

OUT

V

ON/OFF

V

IN

= 12V, R

LOAD

= 27

Typical Operating Characteristics (continued)

(V

IN

= 36V, Circuit of Figure 2, T

A

= +25°C, unless otherwise noted.)

LOAD TRANSIENT

MAX15020 toc14

200

µs/div

50mV/div
AC-COUPLED

2A

1A

I

OUT

V

OUT

V

IN

= 12V, V

OUT

= 3.3V

LOAD TRANSIENT

MAX15020 toc15

200

µs/div

50mV/div
AC-COUPLED

1.2A

0.2A

V

OUT

I

OUT

V

IN

= 12V, V

OUT

= 3.3V

Advertising