Notes:

1. Saturation level is the maximum charge level before vertical transfer efficiency degradation (out of specification).
2. Saturation level is the maximum charge level before horizontal transfer efficiency degradation (out of specification).
3. Saturation level on output node can be optimized by running the readout register in MPP mode. Nevertheless, such a

method implies that the capacitances of the

Φ

L clocks are roughly 30% higher.

4. Measured with the Correlated Double Sampling (CDS).
5. Dynamic range is defined by the ratio of the saturation level to the temporal rms noise in darkness.
6. With a horizontal frequency maximum of 20 MHz, this value will be improved when decreasing this frequency.

Figure 14. Typical Spectral Response

Rms Output Amplifier Noise

With a Bandwidth of 80MHz

With a Bandwidth < 5MHz

N1

N2

20

5

e-

e-

(4)

Output Frequency = 20 MHz

Output Frequency < 1 MHz

Dark Current

MPP Mode

Non MPP Mode

I01

I02

25

0.6

30

1

pA/cm

2

nA/cm

2

T = 25°C

T = 25°C

Dynamic Range

Exposure Time =10 ms

Readout Time = 2s, FV = 100 kHz

Readout Through One Output

SNR

9800

T = 25°C, Without Binning

(5)

Photo-response Non Uniformity,

σ

PRNU

1

2.5

% VOS

Dark Signal Non Uniformity,

σ

Exposure Time = 10 ms,

Readout Time = 2s, FV = 100 kHz

Readout Through One Output

DSNU

2.2

3

mV

T = 25°C

Horizontal Transfer Efficiency

1 -

ε

H

0.99993

0.99997

(6)

Vertical Transfer Efficiency

1 -

ε

V

0.99998

0.99999

Contrast Transfer Function at
Nyquist Frequency

CTF

67

%

Responsivity

R

8.5

V/µJ/cm

2

With BG38 Filter

Linearity Error

LE

< 1

%

Without Binning

Flatness (Peak To Peak)

13

20

µm

Table 4. Electro-optical Performance Characteristics (Continued)

Parameter

Symbol

Value

Unit

Remarks

Min

Typ

Max

0

10

20

30

40

50

400

500

600

700

800

900

1000

Wavelength (nm)

Quantum efficiency (%)