1. Drain supply current I

DD

decreases from 10 mA to 8 mA typically when internal sampling clock is disabled (V

INH

= V

DD

=

15V).

Insertion of a serial resistor (typically 100

Ω) at the driver output avoids spurious negative transients.

Table 6. Selection of Operating Modes

Option

Implementation

Note

No Sampling

Φ

ECHA

(3) and

Φ

ECHB

(25) Connected to VDD

S

Φ

ECHA

(4) and S

Φ

ECHB

(24) Unconnected

V

INH

(16) Connected to V

DD

(1)

Sampling By External Clocks

Sampling Clocks Connected to

Φ

ECHA

-

Φ

ECHB

S

Φ

ECHA

and S

Φ

ECHB

Unconnected

V

INH

(16) Connected to V

DD

See Figure 4 for sampling

clock timing

(1)

Reset Control By External Clocks

Ext.

Φ

RA

on

Φ

RA

(5) Input

Ext.

Φ

RB

on

Φ

RB

(21) Input

See Figure 4 for

reset clock timing

Table 7. External

ΦRA, ΦRB, ΦECHA, ΦECHB Clocks Characteristics

Parameter

Symbol

Logic

Values

Unit

Min

Typ

Max

External Reset Clock
Sampling Clock

Φ

RA

,

Φ

RB

,

Φ

ECHA

,

Φ

ECHB

High

12

13

14

V

Low

0.0

0.4

0.6

V

Reset And Sampling Clock
Capacitance

C

Φ

RA

C

Φ

RB

C

Φ

ECHA

C

Φ

ECHB

10

15

pF

Advertising