Table 12. critical fault configuration – Rainbow Electronics MAX16068 User Manual

Page 17

Advertising
background image

______________________________________________________________________________________ 17

MAX16068

6-Channel, Flash-Configurable System Manager

with Nonvolatile Fault Registers

If GPIO6 is configured as the EXTFAULT input/output
and EXTFAULT is pulled low by an external circuit, bit
r1Ch[6] is set.
The SMB Alert (ALERT) bit is set if the MAX16068 has
asserted the SMBus Alert output. Clear by writing a ‘1’.
See the SMBALERT (ALERT) section for more details.

Critical Faults

During normal operation, a fault condition can be stored
in the flash memory by setting the appropriate critical
fault enable bits. Set the appropriate critical fault enable
bits in registers r6Eh–r72h (see Table 12) for a fault con-
dition to trigger a critical fault.

Table 12. Critical Fault Configuration

REGISTER

ADDRESS

FLASH

ADDRESS

BIT

RANGE

DESCRIPTION

6Dh

26Dh

[1:0]

Fault Information to Log
00 = Save failed line flags and ADC values in flash
01 = Save only failed line flags in flash
10 = Save only ADC values in flash
11 = Do not save anything

[2]

1 = Fault log triggered when EXTFAULT is pulled low externally

[7:3]

Not used

6Eh

26Eh

[0]

1 = Fault log triggered when MON1 is below its undervoltage threshold

[1]

1 = Fault log triggered when MON2 is below its undervoltage threshold

[2]

1 = Fault log triggered when MON3 is below its undervoltage threshold

[3]

1 = Fault log triggered when MON4 is below its undervoltage threshold

[4]

1 = Fault log triggered when MON5 is below its undervoltage threshold

[5]

1 = Fault log triggered when MON6 is below its undervoltage threshold

[7:6]

Not used

6Fh

26Fh

[3:0]

Not used

[4]

1 = Fault log triggered when MON1 is above its overvoltage threshold

[5]

1 = Fault log triggered when MON2 is above its overvoltage threshold

[6]

1 = Fault log triggered when MON3 is above its overvoltage threshold

[7]

1 = Fault log triggered when MON4 is above its overvoltage threshold

70h

270h

[0]

1 = Fault log triggered when MON5 is above its overvoltage threshold

[1]

1 = Fault log triggered when MON6 is above its overvoltage threshold

[7:2]

Not used

71h

271h

[7:0]

Not used

72h

272h

[4:0]

Not used

[5]

1 = EXTFAULT pulled low externally causes the device to stop monitoring until EN
is toggled or the autoretry delay expires (see Autoretry/Latch Mode section)
0 = EXTFAULT pulled low externally does not cause the device to stop monitoring

[7:6]

Not used