Operation mode – Rainbow Electronics W9825G6CH User Manual

Page 10

Advertising
background image

W9825G6CH

- 10 -

OPERATION MODE

Fully synchronous operations are performed to latch the commands at the positive edges of CLK.
Table 1 shows the truth table for the operation commands.

Table 1 Truth Table (Note (1) , (2))

COMMAND

DEVICE

STATE

CKEN-1

CKEN

DQM

BS0, 1

A10

A0

−−

A9

A11, A12

CS

RAS

CAS

WE

Bank Active

Idle

H

x

x

v

v

v

L

L

H

H

Bank Precharge

Any

H

x

x

v

L

x

L

L

H

L

Precharge All

Any

H

x

x

x

H

x

L

L

H

L

Write

Active (3)

H

x

x

v

L

v

L

H

L

L

Write with Autoprecharge

Active (3)

H

x

x

v

H

v

L

H

L

L

Read

Active (3)

H

x

x

v

L

v

L

H

L

H

Read with Autoprecharge

Active (3)

H

x

x

v

H

v

L

H

L

H

Mode Register Set

Idle

H

x

x

v

v

v

L

L

L

L

No-operation

Any

H

x

x

x

x

x

L

H

H

H

Burst Stop

Active (4)

H

x

x

x

x

x

L

H

H

L

Device Deselect

Any

H

x

x

x

x

x

H

x

x

x

Auto-refresh

Idle

H

H

x

x

x

x

L

L

L

H

Self-refresh Entry

Idle

H

L

x

x

x

x

L

L

L

H

Self-refresh Exit

Idle

(S.R.)

L

L

H

H

x

x

x

x

x

x

x

x

H

L

x

H

x

H

x

x

Clock Suspend Mode
Entry

Active

H

L

x

x

x

x

x

x

x

x

Power Down Mode Entry

Idle

Active (5)

H

H

L

L

x

x

x

x

x

x

x

x

H

L

x

H

x

H

x

x

Clock Suspend Mode Exit

Active

L

H

x

x

x

x

x

x

x

x

Power Down Mode Exit

Any

(Power

down)

L

L

H

H

x

x

x

x

x

x

x

x

H

L

x

H

x

H

x

x

Data Write/Output Enable

Active

H

x

L

x

x

x

x

x

x

x

Data Write/Output Disable

Active

H

x

H

x

x

x

x

x

x

x

Notes:

(1) v = valid x = Don't care L = Low Level H = High Level

(2) CKEn signal is input level when commands are provided.

CKEn-1 signal is the input level one clock cycle before the command is issued.

(3) These are state of bank designated by BS0, BS1 signals.

(4) Device state is full page burst operation.

(5) Power Down Mode can not be entered in the burst cycle.

When this command asserts in the burst cycle, device state is clock suspend mode.

Advertising