MAX6514/MAX6515

Low-Cost, 2.7V to 5.5V Temperature Switches
in a SOT23

4

_______________________________________________________________________________________

Pin Description

Detailed Description

The MAX6514/MAX6515 fully integrated temperature
switches incorporate a fixed reference, an analog tem-
perature sensor, and a comparator. Pin-selectable 2°C
or 10°C hysteresis keeps the digital output from oscil-
lating when the die temperature approaches the
threshold temperature. The MAX6514 has an active-
high, push-pull output structure that can sink or source
current. The MAX6515 has an active-low, open-drain
output structure that can only sink current. The internal
power-on reset circuit guarantees the logic output is at
its +25°C state for at least 50µs.

Hysteresis Input

The HYST input selects the devices’ temperature hys-
teresis and prevents the output from oscillating when the
temperature approaches the trip point. Connect HYST to
V

CC

for 2°C hysteresis or to GND for 10°C hysteresis.

Logic Temperature Indicators

Overtemperature Indicator (Hot Thresholds)

TOVER and TOVER designations apply to thresholds
above T

A

= +25°C (+35°C, +45°C, +55°C, +65°C,

+75°C, +85°C, +95°C, +105°C, and +115°C). All “hot”
thresholds are positive temperatures.

The overtemperature indicator output is open drain
active low (TOVER) or push-pull active high (TOVER).
TOVER goes low when the die temperature exceeds
the factory-programmed temperature threshold. TOVER
should be pulled up to a voltage no greater than 5.5V
with a 100kΩ pullup resistor. TOVER is a push-pull
active-high CMOS output that goes high when the die
temperature exceeds the factory-programmed temper-
ature threshold.

Undertemperature Indicator (Cold Thresholds)

TUNDER and TUNDER designations apply to thresh-
olds below T

A

= +25°C (+15°C, +5°C, -5°C, -15°C,

-25°C, -35°C, -45°C). The undertemperature indicator
output is open-drain, active low (TUNDER) or push-pull,
active high (TUNDER). TUNDER goes low when the die
temperature goes below the factory-programmed tem-
perature threshold. TUNDER should be pulled up to a
voltage no greater than 5.5V with a 100kΩ pullup resis-
tor. TUNDER is a push-pull active-high CMOS output
that goes high when the die temperature falls below the
factory-programmed temperature threshold.

PIN

MAX6514

MAX6515

NAME

FUNCTION

1, 2

1, 2

GND

Ground

3

3

HYST

Hysteresis Input. Connect to V

CC

for 2°C of hysteresis or to GND for 10°C hysteresis.

4

4

V

CC

Input Supply. Bypass to ground with a 0.1µF capacitor.

5

TOVER

Push-Pull Active-High Output (Hot Threshold). TOVER goes high when the die temperature
exceeds the factory-programmed hot-temperature threshold.

5

TOVER

Open-Drain, Active-Low Output (Hot Threshold). TOVER goes low when the die temperature
exceeds the factory-programmed hot-temperature threshold. Connect to a 100k

pullup

resistor. Can be pulled up to a voltage higher than V

CC

.

5

TUNDER

Push-Pull Active-High Output (Cold Threshold). TUNDER goes high when the die temperature
falls below the factory-programmed cold-temperature threshold.

5

TUNDER

Open-Drain, Active-Low Output (Cold Threshold). TUNDER goes low when the die
temperature goes below the factory-programmed cold-temperature threshold. Connect to a
100k

pullup resistor. Can be pulled up to a voltage higher than V

CC

.

Advertising