Read cycle timing parameters, Write cycle timing parameters – Rainbow Electronics W49F002U User Manual

Page 14

Advertising
background image

W49F002U

-

14

-

AC Characteristics, continued

Read Cycle Timing Parameters

(V

CC

= 5.0V

±

10

%

, V

CC

= 0V, T

A

= 0 to 70

°

C)

PARAMETER SYM. W49F002U-70 W49F002U-90 W49F002U-120 UNIT

MIN.

MAX.

MIN.

MAX.

MIN.

MAX.

Read Cycle Time

T

RC

70 - 90 - 120 - nS

Chip Enable Access Time

T

CE

- 70 - 90 - 120

nS

Address Access Time

T

AA

- 70 - 90 - 120

nS

Output Enable Access Time

T

OE

- 35 - 40 - 50 nS

CE Low to Active Output

T

CLZ

0 - 0 - 0 - nS

OE Low to Active Output

T

OLZ

0 - 0 - 0 - nS

CE

High to High-Z Output

T

CHZ

- 25 - 25 - 30 nS

OE

High to High-Z Output

T

OHZ

- 25 - 25 - 30 nS

Output Hold from Address Change

T

OH

0 - 0 - 0 - nS

Write Cycle Timing Parameters

PARAMETER SYMBOL

MIN.

TYP. MAX. UNIT

Address Setup Time

T

AS

0 - - nS

Address Hold Time

T

AH

50 - - nS

WE and CE Setup Time

T

CS

0 - - nS

WE and CE Hold Time

T

CH

0 - - nS

OE High Setup Time

T

OES

0 - - nS

OE

High Hold Time

T

OEH

0 - - nS

CE

Pulse Width

T

CP

100 - - nS

WE Pulse Width

T

WP

100 - - nS

WE High Width

T

WPH

100 - - nS

Data Setup Time

T

DS

50 - - nS

Data Hold Time

T

DH

10 - - nS

Byte Programming Time

T

BP

- 35 50

µ

S

Erase Cycle Time

T

EC

- 0.1

0.2 S

Note: All AC timing signals observe the following guidelines for determining setup and hold times: