PAUSE 10 mS

LOAD DATA 90

TO

ADDRESS 5555

LOAD DATA 55

TO

ADDRESS 2AAA

LOAD DATA AA

TO

ADDRESS 5555

Notes for software product identification:
1. Data Format: I/O7 - I/O0 (Hex);

Address Format: A14 - A0 (Hex).

2. A1 - A14 = V

IL

.

Manufacture Code is read for A0 = V

IL;

Device Code is read for A0 = V

IH

.

3. The device does not remain in identification mode if

powered down.

4. The device returns to standard operation mode.
5. Manufacturer Code: 1F

Device Code: DC

ENTER PRODUCT

IDENTIFICATION

MODE

(2, 3, 5)

Software Product
Identification Entry

(1)

PAUSE 10 mS

LOAD DATA F0

TO

ADDRESS 5555

LOAD DATA 55

TO

ADDRESS 2AAA

LOAD DATA AA

TO

ADDRESS 5555

EXIT PRODUCT

IDENTIFICATION

MODE

(4)

Software Product
Identification Exit

(1)