background image

DS1858

Dual Temperature-Controlled Resistors with
Three Monitors

14

____________________________________________________________________

MEMORY

LOCATION

(hex)

EEPROM/

SRAM

R/W

DEFAULT

SETTING

(hex)

NAME OF LOCATION

FUNCTION

6F

SRAM

Conversion updates

Bit 7

R/W

0

TAU

This bit goes high after a temperature and
address update has occurred for the
corresponding measurement in bytes 60h to
61h. This bit can be written to a 0 by the user
and monitored to verify that a conversion has
occurred.

6

R/W

0

V

CC

U

This bit goes high after a V

CC

update has

occurred for the corresponding measurement
in bytes 62h to 63h. This bit can be written to
a 0 by the user and monitored to verify that a
conversion has occurred.

5

R/W

0

MON1U

This bit goes high after a MON1 update has
occurred for the corresponding measurement
in bytes 64h to 65h. This bit can be written to
a 0 by the user and monitored to verify that a
conversion has occurred.

4

R/W

0

MON2U

This bit goes high after a MON2 update has
occurred for the corresponding measurement
in bytes 66h to 67h. This bit can be written to
a 0 by the user and monitored to verify that a
conversion has occurred.

3

0

MON3U

This bit goes high after a MON3 update has
occurred for the corresponding measurement
in bytes 68h to 69h. This bit can be written to
a 0 by the user and monitored to verify that a
conversion has occurred.

2

0

0

1

0

X

0

0

X

70

SRAM

R

Alarm flags

Bit 7

TMPhi

This alarm flag goes high when the upper limit
of the temperature setting is violated.

6

TMPlo

This alarm flag goes high when the lower limit
of the temperature setting is violated.

5

V

CC

hi

This alarm flag goes high when the upper limit
of the V

CC

setting is violated.

Main Device (continued)

Advertising