Ata6839 [preliminary, Serial interface: timing – Rainbow Electronics ATA6839 User Manual

Page 12

Advertising
background image

12

4955C–AUTO–09/07

ATA6839 [Preliminary]

8.

Serial Interface: Timing

Parameters

Test Conditions

Timing Chart No.

Symbol

Min. Typ. Max. Unit

DO enable after CS falling edge

C

DO

= 100 pF

1

t

ENDO

200

ns

DO disable after CS rising edge

C

DO

= 100 pF

2

t

DISDO

200

ns

DO fall time

C

DO

= 100 pF

-

t

DOf

100

ns

DO rise time

C

DO

= 100 pF

-

t

DOr

100

ns

DO valid time

C

DO

= 100 pF

10

t

DOVal

200

ns

CS setup time

4

t

CSSethl

225

ns

CS setup time

8

t

CSSetlh

225

ns

CS high time

Input register bit 14 (SCT) = high

9

t

CSh

17

ms

CS high time

Input register bit 14 (SCT) = low

9

t

CSh

2.1

ms

CLK high time

5

t

CLKh

225

ns

CLK low time

6

t

CLKl

225

ns

CLK period time

-

t

CLKp

500

ns

CLK setup time

7

t

CLKSethl

225

ns

CLK setup time

3

t

CLKSetlh

225

ns

DI setup time

11

t

DIset

40

ns

DI hold time

12

t

DIHold

40

ns

Advertising