Flowchart: two button operation figure 5 – Rainbow Electronics DS1669S User Manual

Page 6

Advertising
background image

DS1668, DS1669, DS1669S

081895 6/10

FLOWCHART: TWO BUTTON OPERATION Figure 5

CONTACT CLOSURE

INCREMENT

1/64TH

DC

UC OR DC?

AT UPPER

LIMIT?

UC

BOTH CONTACTS

OPEN?

AT LOWER

LIMIT?

NO

YES

YES

YES

CONTACT CLOSED

CONTINUOUSLY

>1 SEC?

YES

INCREMENT ON

100MS INTERVALS

AT UPPER

LIMIT?

NO

YES

NO

DECREMENT

1/64TH

CONTACT CLOSED

CONTINUOUSLY

>1 SEC?

DECREMENT ON

100MS INTERVALS

AT LOWER

LIMIT?

YES

NO

NO

NO

YES

CONTACT OPEN AND CONTACT CLOSURE TIMING IS 1 sec.

±

10%

Advertising