Device Operation

(Continued)

A typical LVDS input connection is shown in

Figure 9. The

media is driven differentially by an LVDS driver. The line is
terminated with a termination resistor equal to the
impedance of the line being driven. The actual resistor
value is media specific, but typically is between 100 and

120

. This resistor should be located close to the

CLC001 inputs pins to minimize the resulting stub length
between the resistor and device pads. The CLC001
supports

±

100mV thresholds across the entire LVDS

common mode range of 0.1V to 2.3V for a 200mV
differential signal.

DS101329-9

FIGURE 9. LVDS, DC-coupled

CLC001

www.national.com