Usi status register – usisr, Attiny2313 – Rainbow Electronics ATtiny2313 User Manual

Page 147

Advertising
background image

147

ATtiny2313

2543A–AVR–08/03

Note that the corresponding Data Direction Register to the pin must be set to one for
enabling data output from the Shift Register.

USI Status Register – USISR

The Status Register contains interrupt flags, line status flags and the counter value.

• Bit 7 – USISIF: Start Condition Interrupt Flag

When Two-wire mode is selected, the USISIF flag is set (to one) when a start condition
is detected. When output disable mode or Three-wire mode is selected and (USICSx =
0b11 & USICLK = 0) or (USICS = 0b10 & USICLK = 0), any edge on the SCK pin sets
the flag.

An interrupt will be generated when the flag is set while the USISIE bit in USICR and the
Global Interrupt Enable Flag are set. The flag will only be cleared by writing a logical one
to the USISIF bit. Clearing this bit will release the start detection hold of USCL in Two-
wire mode.

A start condition interrupt will wakeup the processor from all sleep modes.

• Bit 6 – USIOIF: Counter Overflow Interrupt Flag

This flag is set (one) when the 4-bit counter overflows (i.e., at the transition from 15 to
0). An interrupt will be generated when the flag is set while the USIOIE bit in USICR and
the Global Interrupt Enable Flag are set. The flag will only be cleared if a one is written
to the USIOIF bit. Clearing this bit will release the counter overflow hold of SCL in Two-
wire mode.

A counter overflow interrupt will wakeup the processor from Idle sleep mode.

• Bit 5 – USIPF: Stop Condition Flag

When Two-wire mode is selected, the USIPF flag is set (one) when a stop condition is
detected. The flag is cleared by writing a one to this bit. Note that this is not an interrupt
flag. This signal is useful when implementing Two-wire bus master arbitration.

• Bit 4 – USIDC: Data Output Collision

This bit is logical one when bit 7 in the Shift Register differs from the physical pin value.
The flag is only valid when Two-wire mode is used. This signal is useful when imple-
menting Two-wire bus master arbitration.

• Bits 3..0 – USICNT3..0: Counter Value

These bits reflect the current 4-bit counter value. The 4-bit counter value can directly be
read or written by the CPU.

The 4-bit counter increments by one for each clock generated either by the external
clock edge detector, by a Timer/Counter0 overflow, or by software using USICLK or
USITC strobe bits. The clock source depends of the setting of the USICS1..0 bits. For
external clock operation a special feature is added that allows the clock to be generated
by writing to the USITC strobe bit. This feature is enabled by write a one to the USICLK
bit while setting an external clock source (USICS1 = 1).

Bit

7

6

5

4

3

2

1

0

USISIF

USIOIF

USIPF

USIDC

USICNT3

USICNT2

USICNT1

USICNT0

USISR

Read/Write

R/W

R/W

R/W

R

R/W

R/W

R/W

R/W

Initial Value

0

0

0

0

0

0

0

0