Electrical characteristics (continued) – Rainbow Electronics ATA6664 User Manual

Page 12

Advertising
background image

12

9146E–AUTO–03/11

Atmel ATA6663/ATA6664

5

INH Output Pin

5.1

High-level voltage

Normal or fail-safe mode
I

INH

= –15mA

8

V

INHH

V

S

0.75

V

S

V

A

5.2

Switch-on resistance between
VS and INH

Normal or fail-safe mode

8

R

INH

30

50

Ω

A

5.3

Leakage current

Sleep mode
V

INH

= 0V/27V, V

S

= 27V

8

I

INHL

–3

+3

µA

A

6

WAKE Pin

6.1

High-level input voltage

3

V

WAKEH

V

S

1V

V

S

+

0.3V

V

A

6.2

Low-level input voltage

I

WAKE

= typically –3µA

3

V

WAKEL

–1V

V

S

3.3V

V

A

6.3

Wake pull-up current

V

S

< 27V

3

I

WAKE

–30

–10

µA

A

6.4

High-level leakage current

V

S

= 27V, V

WAKE

= 27V

3

I

WAKE

–5

+5

µA

A

7

LIN Bus Driver

7.1

Driver recessive output voltage

R

LOAD

= 500

Ω

/ 1k

Ω

6

V

BUSrec

0.9

×

V

S

V

S

V

A

7.2

Driver dominant voltage
V

BUSdom_DRV_LoSUP

V

VS

= 7V, R

load

= 500

Ω

6

V

_LoSUP

1.2

V

A

7.3

Driver dominant voltage
V

BUSdom_DRV_HiSUP

V

VS

= 18V, R

load

= 500

Ω

6

V

_HiSUP

2

V

A

7.4

Driver dominant voltage
V

BUSdom_DRV_LoSUP

V

VS

= 7V, R

load

= 1000

Ω

6

V

_LoSUP_1k

0.6

V

A

7.5

Driver dominant voltage
V

BUSdom_DRV_HiSUP

V

VS

= 18V, R

load

= 1000

Ω

6

V

_HiSUP_1k_

0.8

V

A

7.6

Pull-up resistor to V

S

The serial diode is mandatory

6

R

LIN

20

30

47

k

Ω

A

7.7

Voltage drop at the serial diodes

In pull-up path with R

slave

I

SerDiode

= 10mA

6

V

SerDiode

0.4

1.0

V

D

7.8

LIN current limitation
V

BUS

= V

BAT_max

6

I

BUS_LIM

40

120

200

mA

A

7.9

Input leakage current at the
receiver, including pull-up
resistor as specified

Input leakage current
Driver off
V

BUS

= 0V, V

S

= 12V

6

I

BUS_PAS_dom

–1

mA

A

7.10

Leakage current LIN recessive

Driver off
8V < V

BAT

< 18V

8V < V

BUS

< 18V

V

BUS

V

BAT

6

I

BUS_PAS_rec

10

20

µA

A

7.11

Leakage current at ground loss;
control unit disconnected from
ground; loss of local ground must
not affect communication in the
residual network

GND

Device

= V

S

V

BAT

=12V

0V < V

BUS

< 18V

6

I

BUS_NO_Gnd

–10

+0.5

+10

µA

A

6.

Electrical Characteristics (Continued)

5V < V

S

< 27V, T

j

= –40°C to +150°C

No.

Parameters

Test Conditions

Pin

Symbol

Min.

Typ.

Max.

Unit

Type*

*) Type means: A = 100% tested, B = 100% correlation tested, C = Characterized on samples, D = Design parameter

Advertising