Ac programming characteristics – Rainbow Electronics AT27BV010 User Manual

Page 8

Advertising
background image

AT27BV010

8

Notes:

1. V

CC

must be applied simultaneously or before V

PP

and removed simultaneously or after V

PP

.

2. This parameter is only sampled and is not 100% tested. Output Float is defined as the point where data is no longer driven—

see timing diagram.

3. Program Pulse width tolerance is 100

µ

sec

±

5%.

Note:

1. The AT27BV010 has the same Product Identification Code as the AT27C010. Both are programming compatible.

AC Programming Characteristics

T

A

= 25

±

5°C, V

CC

= 6.5

±

0.25V, V

PP

= 13.0

±

0.2V

Symbol

Parameter

Test Conditions

(1)

Limits

Units

Min

Max

t

AS

Address Setup Time

Input Rise and Fall Times:

(10% to 90%) 20 ns

Input Pulse Levels:

0.45V to 2.4V

Input Timing Reference Level:

0.8V to 2.0V

Output Timing Reference Level:

0.8V to 2.0V

2

µ

s

t

CES

CE Setup Time

2

µ

s

t

OES

OE Setup Time

2

µ

s

t

DS

Data Setup Time

2

µ

s

t

AH

Address Hold Time

0

µ

s

t

DH

Data Hold Time

2

µ

s

t

DFP

OE High to Output Float Delay

(2)

0

130

ns

t

VPS

V

PP

Setup Time

2

µ

s

t

VCS

V

CC

Setup Time

2

µ

s

t

PW

PGM Program Pulse Width

(3)

95

105

µ

s

t

OE

Data Valid from OE

150

ns

t

PRT

V

PP

Pulse Rise Time During

Programming

50

ns

Atmel’s 27BV010 Integrated Product Identification Code

(1)

Codes

Pins

Hex

Data

A0

O7

O6

O5

O4

O3

O2

O1

O0

Manufacturer

0

0

0

0

1

1

1

1

0

1E

Device Type

1

0

0

0

0

0

1

0

1

05

Advertising