Software product identification entry(1), Software product identification exit(1), Boot block lockout feature enable algorithm(1) – Rainbow Electronics AT29LV020 User Manual

Page 11: Software product identification entr y, Software product identification exit, Boot block lockout feature enable algorithm

Advertising
background image

11

AT29LV020

0565C–FLASH–05/02

Software Product Identification Entry

(1)

Software Product Identification Exit

(1)

Notes:

1. Data Format: I/O7 - I/O0 (Hex);

Address Format: A14 - A0 (Hex).

2. A1 - A17 = V

IL

.

Manufacturer Code is read for A0 = V

IL

;

Device Code is read for A0 = V

IH

.

3. The device does not remain in identification mode if

powered down.

4. The device returns to standard operation mode.
5. Manufacturer Code is 1F. The Device Code is BA.

LOAD DATA AA

TO

ADDRESS 5555

LOAD DATA 55

TO

ADDRESS 2AAA

LOAD DATA 90

TO

ADDRESS 5555

PAUSE 20 mS

ENTER PRODUCT

IDENTIFICATION

MODE

(2)(3)(5)

LOAD DATA AA

TO

ADDRESS 5555

LOAD DATA 55

TO

ADDRESS 2AAA

LOAD DATA F0

TO

ADDRESS 5555

PAUSE 20 mS

EXIT PRODUCT

IDENTIFICATION

MODE

(4)

Boot Block Lockout
Feature Enable Algorithm

(1)

Notes:

1. Data Format: I/O7 - I/O0 (Hex);

Address Format: A14 - A0 (Hex).

2. Lockout feature set on lower address boot block.
3. Lockout feature set on higher address boot block.

LOAD DATA AA

TO

ADDRESS 5555

LOAD DATA 55

TO

ADDRESS 2AAA

LOAD DATA 80

TO

ADDRESS 5555

LOAD DATA AA

TO

ADDRESS 5555

LOAD DATA 55

TO

ADDRESS 2AAA

LOAD DATA 40

TO

ADDRESS 5555

LOAD DATA 00

TO

ADDRESS 00000H

(2)

PAUSE 20 mS

LOAD DATA FF

TO

ADDRESS 3FFFFH

(3)

PAUSE 20 mS

Advertising