Ata6827 [preliminary, Application circuit, Figure 10-1. application circuit – Rainbow Electronics ATA6827 User Manual

Page 13: And v, Micro- controller

Advertising
background image

13

4912C–AUTO–10/06

ATA6827 [Preliminary]

10. Application Circuit

Figure 10-1. Application Circuit

11. Application Notes

It is strongly recommended to connect the blocking capacitors at V

CC

and V

S

as close as possi-

ble to the power supply and GND pins.

Recommended value for capacitors at V

S

:

Electrolytic capacitor C > 22 µF in parallel with a ceramic capacitor C = 100 nF. The value for
electrolytic capacitor depends on external loads, conducted interferences and reverse conduct-
ing current I

Out1,2,3

(see

Section 4. ”Absolute Maximum Ratings” on page 7

).

Recommended value for capacitors at V

CC

:

Electrolytic capacitor C > 10 µF in parallel with a ceramic capacitor C = 100 nF.

To reduce thermal resistance it is recommended to place cooling areas on the PCB as close as
possible to the GND pins and to the die pad.

V

CC

V

CC

V

CC

+

Fault

detector

Fault

detector

n.
u.

n.
u.

n.
u.

n.
u.

n.
u.

n.
u.

n.
u.

n.
u.

H
S

2

L

S

2

H
S

1

L

S

1

Control

logic

5

CLK

7

DO

8

INH

U5021M

Watchdog

Enable

Reset

T

rigger

3

CS

4

DI

Input register
Ouput register

Serial interface

H
S

3

L

S

3

H
S

2

L

S

2

H
S

1

L

S

1

S
R
R

H
S

3

L

S

3

O

S
C

P
S
F

Fault

detector

Micro-

controller

n.
u.

n.
u.

n.
u.

T
P

n.
u.

n.
u.

n.
u.

O

P

L

S
C
D

Fault

detector

Fault

detector

Power on

reset

Charge

pump

UV

protection

Thermal

protection

Fault

detector

VS

V

S

13V

V

Batt

5V

V

CC

BYT41D

+

10

VCC

9

GND

6

GND

18

GND

17

GND

14

OUT3

2

OUT1

15

OUT2

M

M

12

VS

11

Advertising