Ds1874 sfp+ controller with digital ldd interface – Rainbow Electronics DS1874 User Manual

Page 83

Advertising
background image

DS1874

SFP+ Controller with Digital LDD Interface

______________________________________________________________________________________

83

Table 02h, Register FAh: WRITE

FACTORY

DEFAULT

00h

READ ACCESS

PW2 or (PW1 and RWTBL246) or (PW1 and RTBL246)

WRITE ACCESS

PW2 or (PW1 and RWTBL246)

MEMORY

TYPE Volatile

FAh 2

7

2

6

2

5

2

4

2

3

2

2

2

1

2

0

BIT

7

BIT

0

This byte is used during manual 3-wire communication. When a manual write is initiated, this register contain s
the data for the operation.

FACTORY

DEFAULT

00h

READ ACCESS

PW2 or (PW1 and RWTBL246) or (PW1 and RTBL246)

WRITE

ACCESS N/A

MEMORY TYPE

Volatile

FBh 2

7

2

6

2

5

2

4

2

3

2

2

2

1

2

0

BIT

7

BIT

0

This byte is used during maunual 3-wire communication. When a manual read is initiated, the return data is
stored in this register.

FACTORY

DEFAULT

00h

READ ACCESS

PW2 or (PW1 and RWTBL246) or (PW1 and RTBL246)

WRITE

ACCESS N/A

MEMORY

TYPE Volatile

FCh 2

7

2

6

2

5

2

4

2

3

2

2

2

1

2

0

BIT

7

BIT

0

MAX3798/MAX3799 register. This value is read from the MAX3798/MAX3799 with the 3-wire interface every t

RR

(see the MAX3798/MAX3799 electrical characteristics).

Table 02h, Register FBh: READ

Table 02h, Register FCh: TXSTAT1