Modectrl register – Rainbow Electronics AT77C104B User Manual

Page 13

Advertising
background image

13

AT77C104B

5347B–BIOM–08/04

Modectrl Register

Register Name:Modectrl (7 bits)

Access Type:Read/Write

Function:Mode control

MODE: select operating mode

0000: standby

0001: test (reserved for factory use)

0010: click

0100: navigation

1000: acquisition

Certain changes can be made. For example, MODE can be set to 0b0110 to activate
click and navigation.

ANALOGRST: reset local oscillator

0: oscillator in active mode

1: oscillator in power-down mode

Notes:

1. Click or navigation modes cannot be used when the local oscillator is switched off. .
2. To return to standby mode and stop the oscillator (to save on power consumption),

two Modectrl register accesses are

necessary: the first one to select standby mode and the second to switch off the
oscillator.

3. The read-only registers cannot be read when the oscillator is turned off.
4. To shift between navigation and acquisition modes, you must be in standby mode

(Modectrl = 0b00001).

If modes such as “acquisition and click” or “acquisition and navigation” are programmed
together, they will be ignored by the system.

With x = 0 or 1.

b6

b5

b4

b3

b2

b1

b0

MODE (MSB)

MODE

MODE

MODE (LSB)

ANALOGRST

0

0

0

0

1

0

0

Programmed Mode

Register Value

11xx

01xx

1x1x

0x1x

Advertising