Ata6831, 2 power-supply fail, 3 open-load detection – Rainbow Electronics ATA6831 User Manual

Page 6

Advertising
background image

6

4908D–AUTO–09/06

ATA6831

After power-on reset, the input register has the following status:

The following patterns are used to enable internal test modes of the IC. Do not use these pat-
terns during normal operation.

3.2

Power-supply Fail

If undervoltage is detected at pin VS, the power-supply fail bit (PSF) in the output register is set
and all outputs are disabled. To detect an undervoltage, its duration has to last longer than the
undervoltage detection delay time t

dUV

. The outputs are enabled immediately when the supply

voltage returns to the normal operational value. The PSF bit stays high until it is reset by the
SRR bit in the input register.

3.3

Open-load Detection

If the open-load detection bit (OLD) is set to low, a pull-up current for each high-side switch and
a pull-down current for each low-side switch is turned on (open-load detection current I

OUT1-3

). If

the current through the external load does not reach the open-load detection current, the corre-
sponding bit of the output in the output register is set to high.

Switching on an output stage with the OLD bit set to low disables the open-load function for this
output.

Bit 15

SI

Bit 14

OCS

Bit 13

OLD

Bit 12

PH3

Bit 11

PL3

Bit 10

PH2

Bit 9

PL2

Bit 8

PH1

Bit 7

PL1

Bit 6

HS3

Bit 5

LS3

Bit 4

HS2

Bit 3

LS2

Bit 2

HS1

Bit 1

LS1

Bit 0

SRR

H

H

H

L

L

L

L

L

L

L

L

L

L

L

L

L

Bit 15 Bit 14

Bit 13

(OCS)

Bit 12

Bit 11

Bit 10

Bit 9

Bit 8

Bit 7

Bit 6

(HS3)

Bit 5

(LS3)

Bit 4

(HS2)

Bit 3

(LS2)

Bit 2

(HS1)

Bit 1

(LS1)

Bit 0

(SRR)

H

H

H

H

H

L

L

L

L

L

L

L

L

L

L

L

H

H

H

L

L

H

H

L

L

L

L

L

L

L

L

L

H

H

H

L

L

L

L

H

H

L

L

L

L

L

L

L