Ac characteristics – Rainbow Electronics AT24C64 User Manual

Page 5

Advertising
background image

5

AT24C32/64

0336I–SEEPR–07/02

Note:

1. This parameter is characterized and is not 100% tested.

AC Characteristics

Applicable over recommended operating range from T

A

= -40

°C to +85°C, V

CC

= +1.8V to +5.5V, CL = 1 TTL Gate and 100

pF (unless otherwise noted).

Symbol

Parameter

1.8-volt

2.7-, 2.5-volt

5.0-volt

Units

Min

Max

Min

Max

Min

Max

f

SCL

Clock Frequency, SCL

100

100

400

kHz

t

LOW

Clock Pulse Width Low

4.7

4.7

1.2

µs

t

HIGH

Clock Pulse Width High

4.0

4.0

0.6

µs

t

I

Noise Suppression Time

(1)

100

100

50

ns

t

AA

Clock Low to Data Out Valid

0.1

4.5

0.1

4.5

0.1

0.9

µs

t

BUF

Time the bus must be free
before a new transmission can start

(1)

4.7

4.7

1.2

µs

t

HD.STA

Start Hold Time

4.0

4.0

0.6

µs

t

SU.STA

Start Set-up Time

4.7

4.7

0.6

µs

t

HD.DAT

Data In Hold Time

0

0

0

µs

t

SU.DAT

Data In Set-up Time

200

200

100

ns

t

R

Inputs Rise Time

(1)

1.0

1.0

0.3

µs

t

F

Inputs Fall Time

(1)

300

300

300

ns

t

SU.STO

Stop Set-up Time

4.7

4.7

0.6

µs

t

DH

Data Out Hold Time

100

100

50

ns

t

WR

Write Cycle Time

20

10

10

ms

Endurance

(1)

5.0V, 25

°C, Page Mode

1M

1M

1M

Write

Cycles

Advertising