Command definition (in hex), Absolute maximum ratings – Rainbow Electronics AT49BV512 User Manual

Page 4

Advertising
background image

4

AT49BV512

1026E–FLASH–06/02

Notes:

1. The 8K byte boot sector has the address range 0000H to 1FFFH.
2. Either one of the Product ID exit commands can be used.

Command Definition (in Hex)

Command
Sequence

Bus

Cycles

1st Bus

Cycle

2nd Bus

Cycle

3rd Bus

Cycle

4th Bus

Cycle

5th Bus

Cycle

6th Bus

Cycle

Addr

Data

Addr

Data

Addr

Data

Addr

Data

Addr

Data

Addr

Data

Read

1

Addr

D

OUT

Chip Erase

6

5555

AA

2AAA

55

5555

80

5555

AA

2AAA

55

5555

10

Byte
Program

4

5555

AA

2AAA

55

5555

A0

Addr

D

IN

Boot Block
Lockout

(1)

6

5555

AA

2AAA

55

5555

80

5555

AA

2AAA

55

5555

40

Product ID
Entry

3

5555

AA

2AAA

55

5555

90

Product ID
Exit

(2)

3

5555

AA

2AAA

55

5555

F0

Product ID
Exit

(2)

1

XXXX

F0

Absolute Maximum Ratings*

Temperature Under Bias ............................... -55

°C to +125°C

*NOTICE:

Stresses beyond those listed under “Absolute
Maximum Ratings” may cause permanent dam-
age to the device. This is a stress rating only and
functional operation of the device at these or any
other conditions beyond those indicated in the
operational sections of this specification is not
implied. Exposure to absolute maximum rating
conditions for extended periods may affect
device reliability.

Storage Temperature ..................................... -65

°C to +150°C

All Input Voltages
(including NC Pins)
with Respect to Ground ...................................-0.6V to +6.25V

All Output Voltages
with Respect to Ground .............................-0.6V to V

CC

+ 0.6V

Voltage on OE
with Respect to Ground ...................................-0.6V to +13.5V

Advertising