Software product identification entry(1), Software product identification exit(1), Boot block lockout featureenablealgorithm(1) – Rainbow Electronics AT29C020 User Manual

Page 12: Boot block lockout feature enable algorit hm, Software product identification entr y, Software product identification exi t

Advertising
background image

12

AT29C020

0291N–FLASH–07/02

Software Product Identification Entry

(1)

Software Product Identification Exit

(1)

Notes:

1. Data Format: I/O15 - I/O0 (Hex);

Address Format: A14 - A0 (Hex).

2. A1 - A17 = V

IL

.

Manufacturer Code is read for A0 = V

IL

;

Device Code is read for A0 = V

IH

.

3. The device does not remain in identification mode

if powered down.

4. The device returns to standard operation mode.
5. Manufacturer Code is 1F. The Device Code is DA.

LOAD DATA AA

TO

ADDRESS 5555

LOAD DATA 55

TO

ADDRESS 2AAA

LOAD DATA 90

TO

ADDRESS 5555

PAUSE 10 mS

ENTER PRODUCT

IDENTIFICATION

MODE

(2)(3)(5)

LOAD DATA AA

TO

ADDRESS 5555

LOAD DATA 55

TO

ADDRESS 2AAA

LOAD DATA F0

TO

ADDRESS 5555

PAUSE 10 mS

EXIT PRODUCT

IDENTIFICATION

MODE

(4)

Boot Block Lockout
Feature Enable Algorithm

(1)

Notes:

1. Data Format: I/O7 - I/O0 (Hex);

Address Format: A14 - A0 (Hex).

2. Lockout feature set on lower address boot block.
3. Lockout feature set on higher address boot block.

LOAD DATA AA

TO

ADDRESS 5555

LOAD DATA 55

TO

ADDRESS 2AAA

LOAD DATA 80

TO

ADDRESS 5555

LOAD DATA AA

TO

ADDRESS 5555

LOAD DATA 55

TO

ADDRESS 2AAA

LOAD DATA 40

TO

ADDRESS 5555

LOAD DATA 00

TO

ADDRESS 00000H

(2)

PAUSE 20 mS

LOAD DATA FF

TO

ADDRESS 3FFFFH

(3)

PAUSE 20 mS