DC ELECTRICAL CHARACTERISTICS:
DIGITAL THERMOMETER

(-55°C to +125°C; 2.7V

V

DD

5.5V)

PARAMETER

SYMBOL

CONDITION

MIN

TYP

MAX

UNITS

NOTES

DS1721
Thermometer Error

T

ERR

-10°C to +85°C

±1.0

°C

5

Resolution

9

12

bits

9-bit

Conversions

125

150

10-bit

Conversions

250

300

11-bit

Conversions

500

600

Conversion Time

t

CONVT

12-bit

Conversions

1000

1200

ms

AC ELECTRICAL CHARACTERISTICS:
2-WIRE INTERFACE

(-55°C to +125°C; V

DD

=2.7V to 5.5V)

PARAMETER

SYMBOL

CONDITION

MIN

TYP

MAX

UNITS

NOTES

SCL Clock
Frequency

f

SCL

Fast Mode

Standard Mode

0
0

400
100

KHz

Bus Free Time
Between a STOP
and START
Condition

t

BUF

Fast Mode

Standard Mode

1.3
4.7

µs

Hold Time
(Repeated) START
Condition

t

HD:STA

Fast Mode

Standard Mode

0.6
4.0

µs

6

Low Period of
SCL Clock

t

LOW

Fast Mode

Standard Mode

1.3
4.7

µs

High Period of
SCL Clock

t

HIGH

Fast Mode

Standard Mode

0.6
4.0

µs

Setup Time for a
Repeated START
Condition

t

SU:STA

Fast Mode

Standard Mode

0.6
4.7

µs

Data Hold Time

t

HD:DAT

Fast Mode

Standard Mode

0
0

0.9

µs

7

Data Set-up Time

t

SU:DAT

Fast Mode

Standard Mode

100
250

ns

8

Rise Time of both
SDA and SCL
Signals

t

R

Fast Mode

Standard Mode

20+0.1

C

B

300

1000

ns

8

Fall Time of both
SDA and SCL
Signals

t

F

Fast Mode

Standard Mode

20+0.1

C

B

300

1000

ns

9

Set-up time for
STOP Condition

t

SU:STO

Fast Mode

Standard Mode

0.6
4.0

µs

Capacitive Load for
each Bus Line

C

b

400

pF

9

Input Capacitance

C

I

5

pF