Dc and ac operating range, Operating modes, Dc characteristics – Rainbow Electronics AT28C64X User Manual

Page 4: At28c64(x)

Advertising
background image

AT28C64(X)

4

Notes:

1. X can be V

IL

or V

IH

.

2. Refer to AC programming waveforms.

3. V

H

= 12.0V

±

0.5V.

DC and AC Operating Range

AT28C64-12

AT28C64-15

AT28C64-20

AT28C64-25

Operating
Temperature (Case)

Com.

0°C - 70°C

0°C - 70°C

0°C - 70°C

0°C - 70°C

Ind.

-40°C - 85°C

-40°C - 85°C

-40°C - 85°C

-40°C - 85°C

V

CC

Power Supply

5V

± 10%

5V

± 10%

5V

± 10%

5V

± 10%

Operating Modes

Mode

CE

OE

WE

I/O

Read

V

IL

V

IL

V

IH

D

OUT

Write

(2)

V

IL

V

IH

V

IL

D

IN

Standby/Write Inhibit

V

IH

X

(1)

X

High Z

Write Inhibit

X

X

V

IH

Write Inhibit

X

V

IL

X

Output Disable

X

V

IH

X

High Z

Chip Erase

V

IL

V

H

(3)

V

IL

High Z

DC Characteristics

Symbol

Parameter

Condition

Min

Max

Units

I

LI

Input Load Current

V

IN

= 0V to V

CC

+ 1V

10

µA

I

LO

Output Leakage Current

V

I/O

= 0V to V

CC

10

µA

I

SB1

V

CC

Standby Current CMOS

CE = V

CC

- 0.3V to V

CC

+ 1.0V

100

µA

I

SB2

V

CC

Standby Current TTL

CE = 2.0V to V

CC

+ 1.0V

Com.

2

mA

Ind.

3

mA

I

CC

V

CC

Active Current AC

f = 5 MHz; I

OUT

= 0 mA

CE = V

IL

Com.

30

mA

Ind.

45

mA

V

IL

Input Low Voltage

0.8

V

V

IH

Input High Voltage

2.0

V

V

OL

Output Low Voltage

I

OL

= 2.1 mA

= 4.0 mA for RDY/BUSY

0.45

V

V

OH

Output High Voltage

I

OH

= -400

µA

2.4

V

Advertising