6. FUNCTIONAL DESCRIPTION

There are two operational modes: address trigger (

NORM

) and direct trigger (

MODE

). After a new

condition is selected on

NORM

/

MODE

, the power must be cycled to enable it.

6.1.

A

DDRESS

T

RIGGER

(

NORM

)

O

PERATION

The start address bits (

S0

,

S1

,

S2

&

S3

) and end address bits (

E0

,

E1

,

E2

&

E3

) are used

to access the memory location and they can divide the memory into a maximum of 16 slots. As
an example of I1916, they are defined as follows:

S3

(

E3 )

S2

(

E2 )

S1

(

E1)

S0

(

E0 )

Row #

I1916

Duration [s]

0 0 0

0 0

0

0 0 0

1 8 1.0

0 0 1

0

16 2.0

0 0 1

1

24 3.0

0 1 0

0

32 4.0

0 1 0

1

40 5.0

0 1 1

0

48 6.0

0 1 1

1

56 7.0

1 0 0

0

64 8.0

1 0 0

1

72 9.0

1 0 1

0

80 10.0

1 0 1

1

88 11.0

1 1 0

0

96 12.0

1 1 0

1

104 13.0

1 1 1

0

112 14.0

1 1 1

1

120 15.0

6.1.1. Record (

REC

) Operation

• Low active input, level-hold for level-trigger or falling edge for edge-trigger with debounce required.
• For 8kHz sampling frequency, if

REC

is held at Low for a period equal to 1 sec or more, then level

recording is activated. However, if

REC

is pulsed Low for less than 1 sec, then edge-trigger recording

is initiated.

• For 6.4kHz sampling frequency, if

REC

is held at Low for a period equal to 1.25 sec or more, then level

recording is activated. However, if

REC

is pulsed Low for less than 1.25 sec, then edge-trigger

recording is initiated.

• Recording begins from the start address to end address and

LED

is on.

• Recording ceases whenever

REC

returns to High in level-hold mode or a subsequent lower going

pulse appears while in edge-trigger mode or when end address is reached. Then an EOM marker is
written at the end of message. And

LED

is off.

• Then the device will automatically power down.
• This pin has an internal pull-up device.
• Once

REC

is active, input on

FT

,

NORM

/

MODE

,

S0

,

S1

,

S2

,

S3

,

E0

,

E1

,

E2

or

E3

is

illegal.