Ac characteristics for the at22lv10l, Input test waveforms and measurement levels, Output test loads – Rainbow Electronics AT22LV10L User Manual

Page 5: Commercial, At22lv10(l)

Advertising
background image

AT22LV10(L)

5

Input Test Waveforms and
Measurement Levels

Output Test Loads

Commercial

AC Characteristics for the AT22LV10L

Symbol

Parameter

AT22LV10L-25

Units

Min

Typ

Max

t

PD

Input or Feedback to Non-Registered Output

15

25

ns

t

EA

Input to Output Enable

15

25

ns

t

ER

Input to Output Disable

15

25

ns

t

CF

Clock to Feedback

0

5

9

ns

t

CO

Clock to Output

0

10

14

ns

t

SF

Feedback Setup Time

12

7

ns

t

S

Input Setup Time

17

15

ns

t

H

Hold Time

0

ns

t

P

Clock Period

12

ns

t

W

Clock Width

6

ns

F

MAX

External Feedback 1/(t

S

+ t

CO

)

32.2

MHz

Internal Feedback 1/(t

SF

+ t

CF

)

47.6

MHz

No Feedback 1/(t

P

)

83.3

MHz

t

AW

Asynchronous Reset Width

25

15

ns

t

AR

Asynchronous Reset Recovery Time

25

15

ns

t

AP

Asynchronous Reset to Registered Output Reset

18

28

ns