4.1

Normal Mode

This is the normal transmitting and receiving mode. The voltage regulator is active and can
source up to 50 mA. The undervoltage detection is activated. The watchdog needs a trigger sig-
nal from NTRIG to avoid resets at NRES. If NRES is switched to low, the IC changes its state to
Fail-safe Mode.

4.2

Silent Mode

A falling edge at EN when TXD is high switches the IC into Silent Mode. The TXD Signal has to
be logic high during the Mode Select window (see

Figure 4-2 on page 9

). The transmission path

is disabled in Silent Mode. The INH output is switched off and the voltage divider is enabled. The
overall supply current from V

Batt

is a combination of the I

VSsi

= 40 µA plus the VCC regulator out-

put current I

VCC

.

The 3.3V/5V regulator with 2% tolerance can source up to 50 mA. The internal slave termination
between the LIN pin and the VS pin is disabled in Silent Mode to minimize the current consump-
tion in the event that the LIN pin is short-circuited to GND. Only a weak pull-up current (typically
10 µA) between the LIN pin and the VS pin is present. Silent Mode can be activated indepen-
dently from the actual level on the LIN, WAKE, or KL_15 pins. If an undervoltage condition
occurs, NRES is switched to low, and the IC changes its state to Fail-safe Mode.

A voltage less than the LIN Pre_Wake detection VLINL at the LIN pin activates the internal LIN
receiver and starts the wake-up detection timer.

Figure 4-2.

Switch to Silent Mode

Del

a

y time

s

ilent mode

t

d

_

s

ilent = m

a

xim

u

m 20

µs

Mode

s

elect window

LIN

s

witche

s

directly to rece

ss

ive mode

t

d

=

3

.2

µs

LIN

VCC

NRE

S

TXD

EN

Normal Mode

S

ilent Mode