Rainbow Electronics DS1677 User Manual

Page 16

Advertising
background image

DS1677

16 of 17

POWER–FAIL WARNING Figure 14

NOTES:

1. All voltages are referenced to ground.
2. I

CCA

is specified with outputs open, CS set to a logic 1, SCLK=500 kHz, oscillator enabled, and A/D

converter enabled.

3. I

ADC

is specified with CS, V

CCO

open and I/O, SCLK at logic zero. A/D converter is enabled.

4. I

CCS

is specified with CS, V

CCO

open and I/O, SCLK at logic zero. A/D converter is disabled.

5. CS has a 40 k

Ω pull–down resistor to ground.

6. Measured at V

IH

=2.0V or V

IL

=0.8V and 10 ns maximum rise and fall time.

7. Measured at V

OH

=2.4V or V

OL

=0.4V.

8. Load capacitance= 25 pF.
9. I

CCO

=100 mA, V

CC

> V

CCTP

.

10. V

CCO

switchover from V

CC

to V

BAT

occurs when V

CC

drops below the lower of V

CCSW

and V

BAT

.

11. Current from V

CC

input pin to V

CCO

output pin.

12. Current from V

BAT

input pin to V

CCO

output pin.

13. Timebase is generated by very accurate crystal oscillator. Accuracy of this time period is based on

the crystal that is used. A typical crystal with a specified load capacitance of 6 pF will provide an
ccuracy within

±100 ppm over the 0°C to 70°C temperature range. For greater accuracy see

DS32KHz data sheet.

14. If the

EOSC

bit in the Control Register is set to a logic 1, t

RPU

is equal to 250 ms plus the start–up

time of the crystal oscillator.

Advertising