Table 1. configuration-byte format, Table 2. conversion-byte format – Rainbow Electronics MAX1099 User Manual

Page 15

Advertising
background image

MAX1098/MAX1099

10-Bit Serial-Output Temperature Sensors

with 5-Channel ADC

_______________________________________________________________________________________

15

Reference Selection

Select between internal and external voltage modes
through bit REF of the configuration byte. Set REF = 1
for internal reference mode and REF = 0 for external
reference mode.

Internal Reference

The MAX1098 has a 2.50V internal reference, while the
MAX1099 has a 1.20V internal reference. Both are fac-
tory trimmed for accuracy. When internal reference is
selected, REF can be used to drive an external load
with 100µA capability. Bypass REF to GND with a 0.1µF
minimum capacitance. Wake-up time is C x 2.5 x 10

4

s

for the MAX1098 and C x 1.2 x 10

4

s for the MAX1099.

External Reference

The MAX1098 can directly accept reference voltages at
REF from 0.8V to 2.5V, while the MAX1099 can directly
accept reference voltages from 0.8V to 1.2V. Bypass
REF to GND with a 0.1µF capacitor. Temperature mea-
surements always use internal reference.

Power Modes

The MAX1098/(MAX1099) typically requires supply cur-
rents of 380µA (350µA) or 310µA (280µA) when per-
forming voltage conversions at 100% duty cycle with
internal or external references, respectively. The differ-

Table 1. Configuration-Byte Format

BIT 7

(MSB)

BIT 6

BIT 5

BIT 4

BIT 3

BIT 2

BIT 1

BIT 0

(LSB)

Start

0

0

0

0

PM1

PM0

REF

BIT

NAME

DESCRIPTION

7 (MSB)

Start

First logic 1 after CS goes low. (See Input Data Format.)

6, 5, 4, 3

Must be 0000 to load a configuration byte.

2, 1

PM1, PM0

These 2 bits select the desired power mode (Table 3).

0

REF

A logic high enables the internal reference. A logic low disables the internal reference and
selects the external reference mode.

Table 2. Conversion-Byte Format

BIT 7

(MSB)

BIT 6

BIT 5

BIT 4

BIT 3

BIT 2

BIT 1

BIT 0

(LSB)

Start

0

1

0

SEL3

SEL2

SEL1

SEL0

BIT

NAME

DESCRIPTION

7 (MSB)

Start

First logic 1 after CS goes low. (See Input Data Format.)

6, 5, 4

Must be 010 to load a conversion byte.

3, 2, 1, 0

SEL3, SEL2,

SEL1, SEL0

These 4 bits select the input configuration (Table 4).

Figure 6. Detailed SSTRB Timing

t

CSH

t

DO

t

SSTRB

t

CONV

t

SCK

t

CSS

CSB

SSTRB

SCLK

DOUT

PDO CLOCKED IN

SSTRB TIMING