18 registers 67-69h: temperature limit, Table 10. temperature limit vs register setting, Functional description – Rainbow Electronics LM96000 User Manual

Page 23

Advertising
background image

Functional Description

(Continued)

25.7KHz PWM Frequency

PWM Duty Cycle

Level (%)

Value in Decimal

Value in Hex

0

0

0

7.14

1 - 17

01 - 11

14.29

18 - 36

12 - 24

21.43

37 - 54

25 - 36

28.57

55 - 72

37 - 48

35.71

73 - 90

49 - 5A

42.86

91 - 109

5B - 6D

50.00

110 - 127

6E - 7F

57.14

128 - 145

80 - 91

64.29

146 - 164

92 - A4

71.43

165 - 182

A5 - B6

78.57

183 - 200

B7 - C8

85.71

201 - 218

C9 - DA

92.86

219 - 237

DB - ED

100.00

238 - 255

EE - FF

27.7KHz PWM Frequency

PWM Duty Cycle

Level (%)

Value in Decimal

Value in Hex

0

0

0

7.69

1 - 19

01 - 13

15.38

20 - 38

14 - 26

23.08

39 - 58

27 - 3A

30.77

59 - 78

3B - 4E

38.46

79 - 97

4F - 61

27.7KHz PWM Frequency

PWM Duty Cycle

Level (%)

Value in Decimal

Value in Hex

46.15

98 - 117

62 - 75

53.85

118 - 137

76 - 89

61.54

138 - 157

8A - 9D

69.23

158 - 176

9E - B0

76.92

177 - 196

B1 - C4

84.62

197 - 216

C5 - D8

92.31

217 - 235

D9 - EB

100.00

236 - 255

EC - FF

30KHz PWM Frequency

PWM Duty Cycle

Level (%)

Value in Decimal

Value in Hex

0

0

0

8.33

1 - 20

01 - 14

16.67

21 - 42

15 - 2A

25.00

43 - 63

2B - 3F

33.33

64 - 84

40 - 54

41.67

85 - 106

55 - 6A

50.00

107 - 127

6B - 7F

58.33

128 - 148

80 - 94

66.67

149 - 170

95 - AA

75.00

171 - 191

AB - BF

83.33

192 - 212

C0 - D4

91.67

213 - 234

D5 - EA

100.00

235 - 255

EB - FF

4.18 Registers 67-69h: Temperature Limit

Register

Address

Read/

Write

Register

Name

Bit 7

(MSB)

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

(LSB)

Default

Value

Lock?

67h

R/W

Zone1 Fan Temp Limit

7

6

5

4

3

2

1

0

5Ah

U

68h

R/W

Zone2 Fan Temp Limit

7

6

5

4

3

2

1

0

5Ah

U

69h

R/W

Zone3 Fan Temp Limit

7

6

5

4

3

2

1

0

5Ah

U

These are the temperature limits for the individual zones. When the current temperature equals this limit, the fan will be turned
on if it is not already. When the temperature exceeds this limit, the fan speed will be increased according to the algorithm set forth
in the Auto Fan Range, PWM Frequency register description. Default = 90˚C = 5Ah

This register becomes Read Only when the Ready/Lock/Start/Override register Lock bit is set. Any further attempts to write to this
register shall have no effect. After power up the default value is used whenever the Ready/Lock/Start/Override register Start bit
is cleared even though modifications to this register are possible.

TABLE 10. Temperature Limit vs Register Setting

Temperature

Reading (Decimal)

Reading (Hex)

−127˚C

−127

81h

.

.

.

.

.

.

.

.

.

−50˚C

−50

CEh

.

.

.

.

.

.

.

.

.

LM96000

www.national.com

23