5 device id (addr: 000 010; 02h), 6 capabilities fixed (addr: 000 011; 03h), 7 device status (addr: 000 100; 04h) – Rainbow Electronics LM41 User Manual

Page 17: 0 register set

Advertising
background image

2.0 Register Set

(Continued)

2.5 DEVICE ID (Addr: 000 010; 02h)

Reg

Add

Register

Name

R/

W

P

O

R

Val

Bit

15

MSb

Bit

14

Bit

13

Bit

12

Bit

11

Bit

10

Bit

9

Bit

8

Bit

7

Bit

6

Bit

5

Bit

4

Bit

3

Bit

2

Bit

1

Bit

0

LSb

000 010 Device ID

R

24h

RevID

DeviceID

0

0

0

0

0

0

0

0

0

0

1

0

0

1

0

0

The device ID is defined by the manufacturer of the device and is unique for each device produced by a manufacturer. Bits 15-11
identify the revision number of the die and will be incremented upon revision of the device.

Bit

Type

Description

10-0

RO

DeviceID (Device ID Value) A fixed value that identifies the device.

15-11

RO

RevID (Revision ID Value) A fixed value that identifies the device revision.

2.6 CAPABILITIES FIXED (Addr: 000 011; 03h)

Reg

Add

Register

Name

R/

W

P

O

R

Val

Bit

15

MSb

Bit

14

Bit

13

Bit

12

Bit

11

Bit

10

Bit

9

Bit

8

Bit

7

Bit

6

Bit

5

Bit

4

Bit

3

Bit

2

Bit

1

Bit

0

LSb

000 011

Capabilities

Fixed

R

21h

Reserved

FuncDescriptor2

FuncDescriptor1

0

0

0

0

0

0

0

0

0

0

1

0

0

0

0

1

The value of this register defines the capabilities of the LM41. The LM41 supports two functions, that of Temperature
Measurement type (Function 1) and Voltage-Only Measurement type (Function 2). Please refer to the SensorPath specification
for further details on other FuncDescriptor values.

2.7 DEVICE STATUS (Addr: 000 100; 04h)

This register is set to the reset value by a Device Reset.

Reg Add

Register Name

R/

W

P

O

R

Val

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

LSb

000 100

Device Status

R

0h

BER

Res

ERF2

ERF1

Res

SF2

SF1

0

0

0

Bit

Type

Description

0

RO

SF1 (Status Function 1) This bit is set by a Function Event within Function 1. Event details are function

dependent and are described within the function. SF1 is cleared by Device Reset or by handling the event

within the Temperature Measurement Function (see Section 2.9 for further details).

0: Status flag for Function 1 is inactive (no event).

1: Status flag for Function 1 is active indicating that a Function Event has occurred.

1

RO

SF2 (Status Function 2) Same as SF1 for Function 2, Voltage-Only Measurement Function. (see Section

2.10 for further details)

3-2

RO

Reserved. Will always read "0".

4

RO

ERF1 (Error Function 1) This bit is set in response to an error indication within Function 1. ERF1 is cleared

by Device Reset or by handling the error condition within the Temperature Measurement Function (see

Section 2.9 for further details).

0: No error occurred in Function 1.

1: Error occurred in Function 1.

5

RO

ERF2 (Error Function 2) Same as ERF1 for Function 2, Voltage-Only Measurement Function. (see Section

2.10 for further details)

6

RO

Reserved. Will always read "0".