Timing characteristics – Rainbow Electronics MAX1299 User Manual

Page 5

Advertising
background image

MAX1298/MAX1299

12-Bit Serial-Output Temperature Sensors

with 5-Channel ADC

_______________________________________________________________________________________

5

TIMING CHARACTERISTICS

(V

DD

= +4.75V to 5.25V (MAX1298), V

DD

= +2.7V to +3.6V (MAX1299), external reference, V

REF

= +2.5V (MAX1298), V

REF

= +1.2V

(MAX1299), f

SCLK

= 2.5MHz, T

A

= T

MIN

to T

MAX

, unless otherwise noted. Typical values are at T

A

= +25°C.) (Figures 4, 6)

PARAMETER

SYMBOL

CONDITIONS

MIN

TYP

MAX

UNITS

SCLK Frequency

f

SCLK

2.5

MHz

SCLK Pulse Width Low

t

CL

200

ns

SCLK Pulse Width High

t

CH

200

ns

CS Low to SCLK High

t

CSS

100

ns

SCLK High to CS Setup

t

CSH

100

ns

CS Pulse Width

t

CS

100

ns

SCLK High to CS Low Setup

t

CS0

50

ns

SCLK High to CS High Setup

t

CS1

100

ns

DIN Setup to SCLK High Time

t

DS

100

ns

DIN Hold Time

t

DH

0

ns

SCLK Fall to Output Data Valid

t

DO

R

L

= 100k

Ω, C

L

= 50pF

150

ns

CS Fall to Output Enable

t

DV

R

L

= 100k

Ω, C

L

= 50pF

150

ns

CS Rise to Output Disable

t

TR

R

L

= 100k

Ω, C

L

= 50pF

50

ns

SSTRB Rise to SCLK Rise

t

SCLK

0

ns

SCLK Fall to SSTRB Fall

t

SSTRB

200

ns

Note 1: Tested at V

DD

= +5.0V (MAX1298) and V

DD

= +3.0V (MAX1299).

Note 2: Relative accuracy is the deviation of the analog value at any code from its theoretical value after the full-scale range has

been calibrated.

Note 3: Conversion time is defined as the number of clock cycles (64 for voltage measurements, 125 for temperature measure-

ments) multiplied by the internal clock period.

Note 4: Individual analog input voltages cannot extend beyond the power-supply rails.
Note 5: Input resistance is typically 250M

Ω; 5µA limit reflects limitations in production testing.

Note 6: Specifications for full-on status assume continuous conversions. Power modes are software selected (Table 4).
Note 7: Measured at V

FS(+4.75V)

- V

FS(+5.25V)

for the MAX1298 and at V

FS(+2.7V)

- V

FS(+3.6V)

for the MAX1299.

Note 8: External load should not change during conversions for specified accuracy.
Note 9: Excludes noise and self-heating effects. Output error for MAX129_C guaranteed by design.
Note 10: External temperature sensing over -40°C to +85°C range, device at +25°C. Guaranteed by design.

Advertising