Table 9. pwm duty vs register setting, 18 registers 67-69h: temperature limit, Table 10. temperature limit vs register setting – Rainbow Electronics LM85 User Manual

Page 21: Functional description

Advertising
background image

Functional Description

(Continued)

TABLE 9. PWM Duty vs Register Setting

Current Duty

Value (Decimal)

Value (Hex)

0%

0

00h

0.3922%

1

01h

.

.

.

.

.

.

.

.

.

25.098%

64

40h

.

.

.

.

.

.

.

.

.

50.196%

128

80h

.

.

.

.

.

.

.

.

.

100%

255

FFh

4.18 Registers 67-69h: Temperature Limit

Register

Address

Read/

Write

Register

Name

Bit 7

(MSB)

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

(LSB)

Default

Value

Lock?

67h

R/W

Zone1 Fan Temp Limit

7

6

5

4

3

2

1

0

5Ah

U

68h

R/W

Zone2 Fan Temp Limit

7

6

5

4

3

2

1

0

5Ah

U

69h

R/W

Zone3 Fan Temp Limit

7

6

5

4

3

2

1

0

5Ah

U

These are the temperature limits for the individual zones. When the current temperature equals this limit, the fan will be turned
on if it is not already. When the temperature exceeds this limit, the fan speed will be increased according to the algorithm set forth
in the Auto Fan Range, PWM Frequency register description. Default = 90˚C = 5Ah

This register becomes Read Only when the Ready/Lock/Start/Override register Lock bit is set. Any further attempts to write to this
register shall have no effect. After power up the default value is used whenever the Ready/Lock/Start/Override register Start bit
is cleared even though modifications to this register are possible.

TABLE 10. Temperature Limit vs Register Setting

Temperature

Reading (Decimal)

Reading (Hex)

−127˚C

−127

81h

.

.

.

.

.

.

.

.

.

−50˚C

−50

CEh

.

.

.

.

.

.

.

.

.

0˚C

0

00h

.

.

.

.

.

.

.

.

.

50˚C

50

32h

.

.

.

.

.

.

.

.

.

127˚C

127

7Fh