Pin description – Rainbow Electronics MAX1885 User Manual

Page 17

Advertising
background image

MAX1778/MAX1880–MAX1885

Quad-Output TFT LCD DC-DC

Converters with Buffer

______________________________________________________________________________________

17

Pin Description

PIN

MAX1778
MAX1881

MAX1880
MAX1882

MAX1883

MAX1884

MAX1885

NAME

FUNCTION

1

1

1

1

FB

Main Step-Up Regulator Feedback Input. Regulates to 1.25V
nominal. Connect a resistive divider from the output (V

MAIN

) to FB

to analog ground (GND).

2

2

2

2

INTG

Main Step-Up Integrator Output. When using the integrator,
connect 1000pF to analog ground (GND). To disable the
integrator, connect INTG to REF.

3

3

3

3

IN

Main Supply Voltage. The supply voltage powers the control
circuitry for all of the regulators and may range from 2.7V to 5.5V.
Bypass with a 0.1µF capacitor between IN and GND, as close to
the pins as possible.

4

4

4

4

BUF+

VCOM Buffer (Operational Transconductance Amplifier) Positive
Feedback Input. Connect to GND to select the internal resistive
divider that sets the positive input to half the amplifier’s supply
voltage (V

BUF+

= V

SUPB

/2).

5

5

5

5

BUF-

VCOM Buffer (Operational Transconductance Amplifier) Negative
Feedback Input

6

6

6

6

SUPB

VCOM Buffer (Operational Transconductance Amplifier) Supply
Voltage

7

7

7

7

BUFOUT

VCOM Buffer (Operational Transconductance Amplifier) Output

8

8

8

8

GND

Analog Ground. Connect to power ground (PGND) underneath the

IC.

9

9

9

9

REF

Internal Reference Bypass Terminal. Connect a 0.22µF ceramic

capacitor from REF to analog ground (GND). External load
capability up to 50µA.

10

10

FBP

Positive Charge-Pump Regulator Feedback Input. Regulates to

1.25V nominal. Connect a resistive divider from the positive
charge-pump output (V

POS

) to FBP to analog ground (GND).

11

11

FBN

Negative Charge-Pump Regulator Feedback Input. Regulates to

0V nominal. Connect a resistive divider from the negative charge-
pump output (V

NEG

) to FBN to the reference (REF).

12

12

10

10

SHDN

Active-Low Shutdown Control Input. Pull

SHDN low to force the

controller into shutdown. If unused, connect

SHDN to IN for normal

operation. A rising edge on

SHDN clears the fault latch.

13

11

SUPL

Low-Dropout Linear Regulator Input Voltage. Can range from 4.5V

to 15V. Bypass with a 1µF capacitor to GND (see Capacitor
Selection and Regulator Stability
). Connect both input pins
together externally.

Advertising