Rainbow Electronics MAX1619 User Manual

Page 7

Advertising
background image

MAX1619

Remote/Local Temperature Sensor with Dual-

Alarm Outputs and SMBus Serial Interface

_______________________________________________________________________________________

7

Figure 1. Functional Diagram

REMOTE

MUX

LOCAL

REMOTE TEMPERATURE

DATA REGISTER

HIGH-TEMPERATURE THRESHOLD

(REMOTE T

HIGH

)

LOW-TEMPERATURE THRESHOLD

(REMOTE T

LOW

)

DIGITAL COMPARATOR

(REMOTE)

LOCAL TEMPERATURE

DATA REGISTER

HIGH-TEMPERATURE THRESHOLD

(REMOTE T

MAX

)

HYSTERESIS THRESHOLD

(REMOTE T

HYST

)

DIGITAL COMPARATOR

(REMOTE OVERTEMP)

COMMAND BYTE

(INDEX) REGISTER

SMBDATA

SMBCLK

ADDRESS

DECODER

READ

WRITE

CONTROL

LOGIC

SMBus

ADD1

ADD0

STBY

STATUS BYTE REGISTER

CONFIGURATION

BYTE REGISTER

CONVERSION RATE

REGISTER

ALERT RESPONSE

ADDRESS REGISTER

SELECTED VIA

SLAVE ADD = 0001 100

ADC

+

DIODE

FAULT

DXP

DXN

GND

V

CC

-

+

-

+

-

8

8

8

8

8

88

2

7

ALERT

OVERT

QS

R

Q

S

R

POL

MAX1619

Advertising