Logic electrical characteristics, Temperature-to-digital converter characteristics, Lm86 – Rainbow Electronics LM86 User Manual

Page 5

Advertising
background image

Temperature-to-Digital Converter Characteristics

(Continued)

Unless otherwise noted, these specifications apply for V

DD

=+3.0Vdc to 3.6Vdc. Boldface limits apply for T

A

= T

J

=

T

MIN

T

A

T

MAX

; all other limits T

A

= T

J

=+25˚C, unless otherwise noted.

Parameter

Conditions

Typical

Limits

Units

(Note 6)

(Note 7)

(Limit)

Local and Remote T_CRIT Default

Temperature Setting

(Note 11)

+85

˚C

Logic Electrical Characteristics

DIGITAL DC CHARACTERISTICS Unless otherwise noted, these specifications apply for V

DD

=+3.0 to 3.6 Vdc. Boldface lim-

its apply for T

A

= T

J

= T

MIN

to T

MAX

; all other limits T

A

= T

J

=+25˚C, unless otherwise noted.

Symbol

Parameter

Conditions

Typical

Limits

Units

(Note 6)

(Note 7)

(Limit)

SMBData, SMBCLK INPUTS

V

IN(1)

Logical “1” Input Voltage

2.1

V (min)

V

IN(0)

Logical “0”Input Voltage

0.8

V (max)

V

IN(HYST)

SMBData and SMBCLK Digital

Input Hysteresis

400

mV

I

IN(1)

Logical “1” Input Current

V

IN

= V

DD

0.005

±

10

µA (max)

I

IN(0)

Logical “0” Input Current

V

IN

= 0 V

−0.005

±

10

µA (max)

C

IN

Input Capacitance

5

pF

ALL DIGITAL OUTPUTS

I

OH

High Level Output Current

V

OH

= V

DD

10

µA (max)

V

OL

SMBus Low Level Output Voltage

I

OL

= 4mA

I

OL

= 6mA

0.4

0.6

V (max)

SMBus DIGITAL SWITCHING CHARACTERISTICS Unless otherwise noted, these specifications apply for V

DD

=+3.0 Vdc to

+3.6 Vdc, C

L

(load capacitance) on output lines = 80 pF. Boldface limits apply for T

A

= T

J

= T

MIN

to T

MAX

; all other limits

T

A

= T

J

= +25˚C, unless otherwise noted. The switching characteristics of the LM86 fully meet or exceed the published specifi-

cations of the SMBus version 2.0. The following parameters are the timing relationships between SMBCLK and SMBData sig-
nals related to the LM86. They adhere to but are not necessarily the SMBus bus specifications.

Symbol

Parameter

Conditions

Typical

Limits

Units

(Note 6)

(Note 7)

(Limit)

f

SMB

SMBus Clock Frequency

100

10

kHz (max)

kHz (min)

t

LOW

SMBus Clock Low Time

from V

IN(0)

max to

V

IN(0)

max

4.7

25

µs (min)

ms (max)

t

HIGH

SMBus Clock High Time

from V

IN(1)

min to V

IN(1)

min

4.0

µs (min)

t

R,SMB

SMBus Rise Time

(Note 12)

1

µs (max)

t

F,SMB

SMBus Fall Time

(Note 13)

0.3

µs (max)

t

OF

Output Fall Time

C

L

= 400pF,

I

O

= 3mA, (Note 13)

250

ns (max)

t

TIMEOUT

SMBData and SMBCLK Time Low for

Reset of Serial Interface (Note 14)

25

35

ms (min)

ms (max)

t

SU;DAT

Data In Setup Time to SMBCLK High

250

ns (min)

t

HD;DAT

Data Out Stable after SMBCLK Low

300

900

ns (min)

ns (max)

t

HD;STA

Start Condition SMBData Low to SMBCLK

Low (Start condition hold before the first

clock falling edge)

100

ns (min)

t

SU;STO

Stop Condition SMBCLK High to SMBData

Low (Stop Condition Setup)

100

ns (min)

t

SU;STA

SMBus Repeated Start-Condition Setup

Time, SMBCLK High to SMBData Low

0.6

µs (min)

LM86

www.national.com

5

Advertising