Electrical characteristics (continued) – Rainbow Electronics MAX742 User Manual

Page 3

Advertising
background image

MAX742

Switch-Mode Regulator with

+5V to ±12V or ±15V Dual Output

_______________________________________________________________________________________

3

Note 1:

Devices are 100% tested to these limits under 0mA to 100mA and to 125mA conditions using automatic test equipment.
The ability to drive loads up to 1A is guaranteed by the current-limit threshold, output swing, and the output current
source/sink tests. See Figures 2 and 3.

Note 2:

Actual load capability of the circuit of Figure 2 is ±200mA in ±15V mode and ±250mA in ±12V mode. Load regulation is
tested at lower limits due to test equipment limitations.

Note 3:

Guaranteed by design.

Note 4:

Measured at Point A, circuit of Figure 2, with PDRV disconnected.

ELECTRICAL CHARACTERISTICS (continued)

(Circuit of Figure 2, V+ = 5V, 100/200 = 12/15 = 0V; T

A

= T

MIN

to T

MAX

, unless otherwise noted.)

EXT+, EXT-, I

L

= -1mA, V+ = 4.5V, PDRV= -3V

EXT+, EXT-, I

L

= 1mA, V+ = 4.5V, PDRV= -3V

V+ = 3.8V, SS = 2V

CC+, CC-

V+ = 4.5V, PDRV = -3V,
T

A

= +25°C

V+ = 4.5V, I

L

= -5mA, T

A

= +25°C

SS = 0V

CONDITIONS

mA

-2

-0.5

Soft-Start Sink Current

µA

3

7

Soft-Start Source Current

V

-2.8

V

OL

V

4.3

V

OH

Output Voltage High

Output Voltage Low

°C

190

Thermal-Shutdown Threshold

k

10

Compensation Pin Impedance

mA

100

200

Output Sink Current

200

350

V

-3

PUMP Output Voltage (Note 4)

UNITS

MIN

TYP

MAX

SYMBOL

PARAMETER

EXT+ = 4.5V

EXT- = 4.5V

EXT+ = 0V

V+ = 4.5V, PDRV = -3V,
T

A

= +25°C

EXT- = -3V

mA

-200

-100

Output Source Current

-350

-200

EXT+, C

LOAD

= 2nF

ns

70

Output Rise/Fall Time

100

EXT-, C

LOAD

= 4nF, PDRV = -3V

Advertising