Multichannel remote/local temperature sensors, Table 8. slave address decoding (add0 and add1) – Rainbow Electronics MAX1989 User Manual

Page 15

Advertising
background image

MAX1668/MAX1805/MAX1989

Multichannel Remote/Local

Temperature Sensors

______________________________________________________________________________________

15

Figure 5. SMBus Write Timing Diagram

Figure 4. SMBus Read Timing Diagram

SMBCLK

A = START CONDITION
B = MSB OF ADDRESS CLOCKED INTO SLAVE
C = LSB OF ADDRESS CLOCKED INTO SLAVE
D = R/W BIT CLOCKED INTO SLAVE

A

B

C

D

E

F

G

H

I

J

SMBDATA

t

SU:STA

t

HD:STA

t

LOW

t

HIGH

t

SU:DAT

t

SU:STO

t

BUF

K

E = SLAVE PULLS SMBDATA LINE LOW
F = ACKNOWLEDGE BIT CLOCKED INTO MASTER
G = MSB OF DATA CLOCKED INTO MASTER
H = LSB OF DATA CLOCKED INTO MASTER

I = ACKNOWLEDGE CLOCK PULSE
J = STOP CONDITION
K = NEW START CONDITION

SMBCLK

A

B

C

D

E

F

G

H

I

J

K

SMBDATA

t

SU:STA

t

HD:STA

t

LOW

t

HIGH

t

SU:DAT

t

HD:DAT

t

SU:STO

t

BUF

A = START CONDITION
B = MSB OF ADDRESS CLOCKED INTO SLAVE
C = LSB OF ADDRESS CLOCKED INTO SLAVE
D = R/W BIT CLOCKED INTO SLAVE
E = SLAVE PULLS SMBDATA LINE LOW

L

M

F = ACKNOWLEDGE BIT CLOCKED INTO MASTER
G = MSB OF DATA CLOCKED INTO SLAVE
H = LSB OF DATA CLOCKED INTO SLAVE
I = SLAVE PULLS SMBDATA LINE LOW

J = ACKNOWLEDGE CLOCKED INTO MASTER
K = ACKNOWLEDGE CLOCK PULSE
L = STOP CONDITION, DATA EXECUTED BY SLAVE
M = NEW START CONDITION

Table 8. Slave Address Decoding (ADD0
and ADD1)

Note: High-Z means that the pin is left unconnected and floating.

0011 001

High-Z

GND

0011 000

ADDRESS

0101 001

GND

High-Z

0011 010

V

CC

GND

0101 011

V

CC

High-Z

0101 010

1001 101

High-Z

V

CC

1001 100

GND

GND

GND

V

CC

High-Z

High-Z

1001 110

V

CC

V

CC

ADD0

ADD1

Advertising