Pipelined Operation

Besides the two standard write-read-mode options,
pipelined operation can be achieved by connecting
WR to RD (Figure 6). With CS low, driving WR and RD
low initiates a conversion and concurrently reads the
result of the previous conversion.

_____________Analog Considerations

Reference

Figures 7a, 7b, and 7c show typical reference connec-
tions. The voltages at REF+ and REF- set the ADC’s
analog input range (see Figure 10). The voltage at REF-
defines the input that produces an output code of all
zeros, and the voltage at REF+ defines the input that
produces an output code of all ones.

The internal resistance from REF+ to REF- can be as
low as 1k

, and current will flow through it even when

the MAX114/MAX118 are shut down. Figure 7d shows
how an N-channel MOSFET can be connected to REF-

MAX114/MAX118

+5V, 1Msps, 4 & 8-Channel,

8-Bit ADCs with 1µA Power-Down

_______________________________________________________________________________________

9

REF-

V

DD

IN_

REF+

V

IN+

V

IN-

GND

+5V

0.1

µ

F

4.7

µ

F

MAX114
MAX118

Figure 7a. Power Supply as Reference

REF-

V

DD

MX584

IN_

REF+

V

IN+

V

IN-

GND

+5V

C1
0.1µF

0.1µF

4.7µF

MAX114
MAX118

Figure 7b. External Reference, 4.096V Full Scale

REF-

REF+

0.1µF

0.1µF

* CURRENT PATH MUST STILL
EXIST FROM V

IN-

TO GND

R*

IN_

V

IN-

V

DD

V

IN+

GND

+5V

+2.5V

4.7µF

0.1µF

MAX114
MAX118

Figure 7c. Input Not Referenced to GND

REF-

V

DD

MAX874

REF+

+5V

0.1µF

0.1µF

C1
3.3µF

PWRDN

PWRDN

N-FET*

* IRML2402

MAX114
MAX118

Figure 7d. An N-channel MOSFET switches off the reference
load during power-down

t

ACQ

t

INTL

RD, WR

INT

NEW DATA (N)

t

WR

t

ACQ

t

AH

t

CSH

t

IHWR

t

CSS

t

ID

OLD DATA (N - 1)

D0–D7

ADDRESS
VALID (N)

ADDRESS

VALID (N + 1)

A0–A2

CS

Figure 6. Pipelined Mode Timing (