Turn on the UPS unit by pressing the power switch. Turn off the UPS unit by pressing again the power switch.


6. Functions & Operation

I: DC Start Function

DC Start Function enables UPS to be started up when AC utility power is not available and battery is fully
charged. Just simply press the power switch to turn on the UPS.

II: Green Power Function
These Series are equipped with Green Power Function. If no load connects to the UPS, it will automatically
shut down in 5 minutes for energy saving while power failure. The UPS will restart while AC recovery.

III: AVR (Automatic Voltage Regulation)
If the quality of the incoming mains is poor, the AVR boosts a low incoming voltage or reduces a high one. The
load receives a voltage within the normal range.

IV: LED Indicator

VI 400SE/600SE/800SE

VI 1000SE/1400SE/2000SE

Green ON

- AC Mode

1

st

Green ON

- AC Mode

Green Flashing

- Backup Mode

1

St

Green Flashing

- Backup Mode

RED LED ON

- Faulty

3

rd

to 5

th

green ON

- Load Level
- Battery Capacity (in
Backup Mode)

NEVER connect a laser printer or scanner to the

UPS unit, because in-rush current generated by

motor’s devices may cause the damage of the unit.