3. Installation and Operation

Inspection

Remove the unit from the shipping package and inspect it for damage that may occurred during

transportation. Notify the carrier and place of purchase if any damage is found.

Connect to the Wall Outlet

Plug the input power cord of the unit to the wall outlet. The Power LED will light up when the

mains is normal. The Power LED will be off while power failure.

Connect UPS

Connect a power cord from UPS input to UPS input socket on the unit. Use provided

power cord to connect UPS output to UPS output socket on the unit.

Online UPS

Connect Equipment

There are two types of output receptacles: Master, and Slave.

To save power consumption, the unit is equipped with Master and Slave output receptacles. The

Master output receptacle will sense if master device (computer) is on. If the master device is no

longer drawing current, it will automatically shut down the power to the Slave output

receptacles. Please refer to below charts for detailed equipment connection.

NOTE: When the computer is turned off, the Master output receptacle shuts off power to the

slave output receptacles. However, when the computer goes into “sleep mode” or the power

consumption of connected device to Master output receptacle is below 20 W, the Master output

receptacle may not properly recognize the reduced power level.

Connect Modem/Phone Port for Surge Protection

Connect a single modem/phone line into surge-protected “IN” outlet on the unit. Connect from

“OUT” outlet to the computer with phone line cable.

4. Operation

Transfer to Maintenance Bypass

Before transferring to maintenance bypass, make sure the Power LED is lighting. Transfer the

rotary bypass switch from “Normal” to “Bypass”. At this time, all connected devices are powered

by the utility power directly. You may turn off the UPS and disconnect two cables connecting to

UPS. Then you may now service the UPS.

Transfer to UPS Protection

After maintenance service is done, reconnect UPS to the unit by following Installation Section.

Verify the Power LED is lighting. Then transfer the rotary bypass switch from “Bypass” to

“Normal”. Now, all connected devices are protected by UPS.

Master/Slave Function Operation

After connecting all devices to the unit, press “Function switch” to enable master/slave

function. The Function LED will light up. Press “Function switch” to disable the function and the

Function LED will be off.

Status & Indicator Table

Status

Indicator

Utility is normal

Power LED (Green) on

Utility fails

Power LED (Green) off

Master/Slave function is enabled

Master/Slave Function LED (Yellow) on

Master/Slave function is disabled

Master/Slave Function LED (Yellow) off

5. Important Safety Warning (SAVE THESE INSTRUCTIONS)

To safely operate this unit, please read and follow all instructions carefully. Read

this manual thoroughly before attempting to unpack, install, or operate. You may

keep this quick guide for further reference.

CAUTION: The product must be used indoor only.

CAUTION: Do not place the unit near liquid or in an excessively damp environment.

CAUTION: Do not place the product directly in the sun or near a hot source.

CAUTION: Do not let liquid or foreign objects enter the product.

CAUTION: Ground the product using a 2P + ground sockets.

CAUTION: When installing the product, ensure that the sum of the leakage currents

of the product and the devices it supplies not exceed 3.5mA.

Plug Computer into

Plug Peripherals into

Master Output Receptacles

Slave Output Receptacles

Computer

Monitor Scanner

Printer

10A(16A)/16A