EN

load ,such as the fridge of 1KW ,the motor of 800W, air cooler ,PC

having risk of

rebooting

and so on. In this mode, the PowerWalker Inverter series operating voltage, in

‘mains’ mode, is within 170~280Vac with the same output voltage. The line sensitivity is
higher.

B.

Select “Wide” setting to save energy. In this mode the operating range of voltage for the
PowerWalker Inverter is 90-280Vac, hence the output voltage will be the same as the
MAINS input voltage. The PowerWalker Inverter unit in this mode has a lower sensitivity.
You can connect and use only for some special load, such as lamp, fan.


Battery Connection

Step 1- Pinch the bottom of DC input cover and Open it.
Step 2- Follow battery polarity guide located near battery terminal. Place the battery cable ring

terminal over PowerWalker Inverter’s battery terminal. Tighten the M5 nut. Do not place
anything between the flat part of battery terminal and the battery cable ring terminal, since
overheating may occur.




















Caution! DO NOT place
anything

between

battery

cable

ring

terminals

and

battery terminals. The terminal
stud is not designed to carry
current.

Apply

Anti-oxidant

paste

to

terminals

after

terminals have been torqued.

Battery Cable Connection to PowerWalker Inverter 1000/2000VA